|
Journal of Ultrasound in Medicine, Vol 9, Issue 9 525-532, Copyright © 1990 by American Institute of Ultrasound in Medicine
Three-dimensional spatial registration and interactive display of position and orientation of real-time ultrasound images
D. L. King, D. L. King Jr and M. Y. Shao
Columbia University College of Physicians and Surgeons, New York, New York 10032.
Ultrasound images may be difficult to interpret because of the lack of an
image orientation display. To resolve this problem, a three-dimensional
(3-D) ultrasound scanner has been constructed that provides spatial
registration and display of position and orientation of real-time images
while allowing unconstrained movement of the scanning transducer. It
consists of a conventional sector scanner, a 3-D acoustical spatial
locater, and a personal computer. It displays within each image the line of
intersection of two image planes, a reference image, and a live image. This
display guides and documents image positioning. The scanner's 3-D data also
provide the potential for computergraphic modeling of organs, the ability
to calculate volumes using nonparallel, nonintersecting image planes, and
the capability for 3-D color flow mapping and measurement of Doppler angle.
This article has been cited by other articles:

|
 |

|
 |
 
D. Gilon, E. G. Cape, M. D. Handschumacher, J.-K. Song, J. Solheim, M. VanAuker, M. E. E. King, and R. A. Levine
Effect of three-dimensional valve shape on the hemodynamics of aortic stenosis: Three-dimensional echocardiographic stereolithography and patient studies
J. Am. Coll. Cardiol.,
October 16, 2002;
40(8):
1479 - 1486.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
D. L. King, L. El-Khoury Coffin, and M. S. Maurer
Myocardial contraction fraction: a volumetric index of myocardial shortening by freehand three-dimensional echocardiography
J. Am. Coll. Cardiol.,
July 17, 2002;
40(2):
325 - 329.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
Y. Otsuji, M. D. Handschumacher, E. Schwammenthal, L. Jiang, J.-K. Song, J. L. Guerrero, G. J. Vlahakes, and R. A. Levine
Insights From Three-Dimensional Echocardiography Into the Mechanism of Functional Mitral Regurgitation : Direct In Vivo Demonstration of Altered Leaflet Tethering Geometry
Circulation,
September 16, 1997;
96(6):
1999 - 2008.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
D. Gilon, E. G. Cape, M. D. Handschumacher, L. Jiang, C. Sears, J. Solheim, E. Morris, J. T. Strobel, S. M. Miller-Jones, A. E. Weyman, et al.
Insights From Three-dimensional Echocardiographic Laser Stereolithography: Effect of Leaflet Funnel Geometry on the Coefficient of Orifice Contraction, Pressure Loss, and the Gorlin Formula in Mitral Stenosis
Circulation,
August 1, 1996;
94(3):
452 - 459.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
A. S. Gopal, Z. Shen, P. M. Sapin, A. M. Keller, M. J. Schnellbaecher, D. W. Leibowitz, O. O. Akinboboye, R. A. Rodney, D. K. Blood, and D. L. King
Assessment of Cardiac Function by Three-dimensional Echocardiography Compared With Conventional Noninvasive Methods
Circulation,
August 15, 1995;
92(4):
842 - 853.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
L. Jiang, J. A. Vazquez de Prada, M. D. Handschumacher, C. Vuille, J. L. Guererro, M. H. Picard, J. T. Joziatis, J. T. Fallon, A. E. Weyman, and R. A. Levine
Quantitative Three-Dimensional Reconstruction of Aneurysmal Left Ventricles : In Vitro and In Vivo Validation
Circulation,
January 1, 1995;
91(1):
222 - 230.
[Abstract]
[Full Text]
|
 |
|
|
|