JUM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Order Full text via Infotrieve
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Koivukangas, J.
Right arrow Articles by Nystrom, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Koivukangas, J.
Right arrow Articles by Nystrom, S.

Journal of Ultrasound in Medicine, Vol 8, Issue 12 675-683, Copyright © 1989 by American Institute of Ultrasound in Medicine


JOURNAL ARTICLE

Completely computer-focused ultrasound imaging. First clinical imaging results

J. Koivukangas, O. Tervonen, E. Alasaarela, J. Ylitalo and S. Nystrom
Department of Neurosurgery, University of Oulu, Finland.

Completely computer-focused ultrasound imaging has been achieved using the UHB (ultrasound holographic B) method. This is a synthetic aperture method that combines ultrasonic holography and the conventional B-scan method. A wide-angle ultrasound burst (4 MHz) is transmitted into the object and the reflected echoes are measured as a function of the propagation time, but both the amplitude and phase angle are recorded, giving multiple one-dimensional holograms in a cross-sectional plane. This UHB data is rearranged to obtain one-dimensional wave fields, which represent the wave fronts reflected from each depth. The image is then reconstructed by propagating these wave fields backward to their original positions on the image using Fourier transform, a spectrum shift theorem, and inverse Fourier transform. The whole UHB image is obtained by calculating the intensity lines from these wave fields and by scanning these lines one by on the cathode ray tube (CRT) monitor. Following extensive laboratory testing with single and multielement transducers, special 32- and 64-element linear array transducers were fabricated, as was computer software capable of producing a UHB image in 40 seconds. Tissue imaging tests followed by clinical imaging of 30 patients showed that images obtained with this prototype compared favorably with those obtained by state-of-the-art conventional ultrasound scanners. The potential advantages of the new method are enhanced lateral resolution and the incorporation of phase information in tissue characterization. This would be important in diagnostic and intraoperative, especially neurosurgical, imaging.