JUM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Order Full text via Infotrieve
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kurtz, A. B.
Right arrow Articles by et, al.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kurtz, A. B.
Right arrow Articles by et, al.

Journal of Ultrasound in Medicine, Vol 3, Issue 7 289-297, Copyright © 1984 by American Institute of Ultrasound in Medicine


JOURNAL ARTICLE

The inaccuracy of total uterine volume measurements: sources of error and a proposed solution

A. B. Kurtz, W. M. Shaw, R. J. Kurtz, M. D. Rifkin, M. E. Pasto, C. Cole-Beuglet, O. H. Baltarowich, R. J. Wapner, P. M. Foy, P. M. Morgan and al. et

Inaccuracies in total intrauterine volumes calculated using the prolate ellipse equation have been reported. No previous study has examined all the sources of error. In this study, a comprehensive approach was undertaken. Measurements were obtained from scans of the pregnant uterus in the prone position using an automated water-path scanner (Octoson) and in the supine position using standard static B-mode scanners. Several conclusions could be drawn: 1) From the Octoson prone scans, uterine volumes obtained using the prolate ellipse formula were markedly different from the true uterine volumes obtained by the summation of stepped areas. This showed that the prolate ellipse formula was inaccurate. 2) From the static supine scans, many observer inconsistencies were found in uterine volumes obtained from the prolate ellipse formula. This made the prolate ellipse formula unreliable. 3) Previously published graphs calculated from the prolate ellipse equation, comparing fetal age with total intrauterine volume, were found to vary accuracy, presumably as a result of 1 and 2. A more accurate approach is proposed. Using the outer uterine wall as the boundary, the stepped area-to-volume values of transverse scans taken at 3-cm intervals were found to closely approximate true volumes, with an average error of only 3.5 per cent. Since these measurements encompass the intrauterine contents and the myometrium, it is suggested that the term "total uterine volume" be used instead of "total intrauterine volume."





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1984 by the American Institute of Ultrasound in Medicine.