JUM Parker Laboratories, Inc
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Google Scholar
Right arrow Articles by Saboo, S. S.
Right arrow Articles by Adhane, V.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Saboo, S. S.
Right arrow Articles by Adhane, V.
© 2009 by the American Institute of Ultrasound in Medicine
J Ultrasound Med 28:1245-1249 • 0278-4297


Case Series

High-Resolution Sonography Is Effective in Detection of Soft Tissue Foreign Bodies

Experience From a Rural Indian Center

Sonali S. Saboo, DMRD, DNB, Suresh H. Saboo, MD, DMRD, Sachin S. Soni, MD, DNB and Vishnu Adhane, DMRD

From Sai Diagnostic and Research Center, Jalna, India (S.S.Sa., S.H.S., S.S.So., V.A.); and Navodaya Medical College, Raichur, India (S.H.S.).

Address correspondence to Suresh H. Saboo, MD, DMRD, Sai Diagnostic and Research Center, Post Office Road, Shivaji Chowk, 431203 Jalna, Maharashtra, India. E-mail: drsureshsaboo{at}rediffmail.com

Objective. Patients with penetrating trauma or field injuries are commonly encountered by emergency physicians. Clinical examination by inspection or palpation can detect superficial foreign bodies (FBs), and radiographs can detect radiopaque FBs. However, soft tissue FBs can be easily missed. The aim of our series was to evaluate the role of high-resolution sonography in detection of soft tissue FBs. Methods. All patients referred to our center for sonographic evaluation of suspected soft tissue FBs from 1999 to 2008 were included in this analysis. Patients were scanned with an ultrasound machine using a 7.5-MHz transducer. The suspected area was scanned in both axial and sagittal planes. The nature of the FB, length, and depth from the surface were recorded and reported. The presence of an FB was confirmed by surgical excision. Results. During the study period, 123 patients underwent sonography for a suspected FB, of which 12 were lost to follow-up and excluded from the analysis. The study group included 73.8% male patients; the mean age was 36.2 years. Wood fragments and wooden thorns were the most frequently observed FBs, at 46.2% and 36.2%, respectively. The surgeon was satisfied with the reported depth of the FB from the surface in most cases (89%). The overall sensitivity and specificity of sonography were 94.5% and 53.8%. Conclusions. High-resolution sonography is a very sensitive tool in diagnosis of soft tissue FBs. It also helps the surgeon with accurate localization, permitting easy removal.

Key Words: emergency department • foreign bodies • high-resolution sonography • radiolucent • soft tissue

Abbreviations: FB, foreign body







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2009 by the American Institute of Ultrasound in Medicine.