JUM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Google Scholar
Right arrow Articles by Hoyt, K.
Right arrow Articles by Robbin, M. L.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hoyt, K.
Right arrow Articles by Robbin, M. L.
© 2009 by the American Institute of Ultrasound in Medicine
J Ultrasound Med 28:1511-1518 • 0278-4297

Accuracy of Volumetric Flow Rate Measurements

An In Vitro Study Using Modern Ultrasound Scanners

Kenneth Hoyt, PhD, Felix A. Hester, RDMS, RVT, Randall L. Bell, RDMS, Mark E. Lockhart, MD, MPH and Michelle L. Robbin, MD

Department of Radiology (K.H., F.A.H., R.L.B., M.E.L., M.L.R.) and Comprehensive Cancer Center (K.H.), University of Alabama at Birmingham, Birmingham, Alabama USA.

Address correspondence to Kenneth Hoyt, PhD, University of Alabama at Birmingham, Volker Hall G082, 1670 University Boulevard, Birmingham, AL 35294 USA., E-mail: hoyt{at}uab.edu

Objective. Volumetric flow measurement with Doppler ultrasound is useful in assessing blood flow as part of an evaluation of arteriovenous fistula maturity in patients undergoing hemodialysis. In this study, we assessed both accuracy and variability in volumetric flow measurements obtained using modern and commercially available ultrasound systems and an in vitro experimental setup. Methods. Volumetric flow measurements using duplex ultrasound were obtained by 3 users operating 5 different systems for randomized flow in the range of 100 to 1000 mL/min. Users performed 3 consecutive measurements at a given flow rate. Data were analyzed using statistical techniques to assess measurement accuracy and variability. Results. Over the span of flow rates studied, the root mean square error (RMSE) for the 5 ultrasound systems ranged from 38.8 to 79.7, 36.8 to 52.0, 73.0 to 85.3, 26.7 to 44.6, and 43.9 to 93.5 mL/min. Corresponding average RMSE values were 60.3, 42.7, 81.1, 37.2, and 64.4 mL/min, respectively. A linear regression analysis of mean interobserver measurements revealed an excellent correlation for all ultrasound systems (r2 > 99.1%). Assessment of intraobserver measurements revealed no statistically significant differences for any ultrasound system evaluated (P > .94). Comparison of interobserver measurements indicates no statistically significant differences between any of the 5 systems (P > .14). Conclusions. Modern ultrasound systems are reasonably accurate in blood flow measurement in an experimental setup mimicking clinically relevant blood flow ranges in a hemodialysis fistula. Users need adequate training and experience to perform multiple measurements and use appropriate techniques to minimize errors in flow measurement.

Key Words: Doppler ultrasound • hemodialysis fistula • volumetric flow

Abbreviations: AVF, arteriovenous fistula • RMSE, root mean square error







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2009 by the American Institute of Ultrasound in Medicine.