JUM Parker Laboratories, Inc
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Google Scholar
Right arrow Articles by Baek, S.-E.
Right arrow Articles by Son, E. J.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Baek, S.-E.
Right arrow Articles by Son, E. J.
© 2009 by the American Institute of Ultrasound in Medicine
J Ultrasound Med 28:1349-1356 • 0278-4297

Effect of Clinical Information on Diagnostic Performance in Breast Sonography

Song-Ee Baek, MD, Min Jung Kim, MD, PhD, Eun-Kyung Kim, MD, PhD, Ji Hyun Youk, MD, PhD, Hye-Jeong Lee, MD and Eun Ju Son, MD, PhD

Department of Radiology, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul, Korea.

Address correspondence to Min Jung Kim, MD, PhD, Department of Radiology, Yonsei University Heath System, 250 Seongsanno, Seodaemun-gu, Seoul 120-752, Korea. E-mail: mines{at}yuhs.ac

Objective. The purpose of this study was to assess whether the clinical information (CI) of patients affects the degree of suspicion for malignancy by radiologists performing breast sonography. Methods. We included 150 breast lesions in 144 patients who underwent breast sonography and sonographically guided core needle biopsy. A pathologic diagnosis was available for all 150 breast lesions: 78 (52%) were malignant, and 72 (48%) were benign. Three radiologists retrospectively reviewed the sonograms of all lesions twice at 8-week intervals first without any CI for the patients (first review) and then with CI such as patient age, palpability, and personal history of risk factors for breast cancer (second review). The reviewers categorized the final assessment according to the American College of Radiology Breast Imaging Reporting and Data System. We compared diagnostic performance such as sensitivity and specificity and the degree of suspicion for malignancy between the image reviews with and without CI. Results. In the second review, sensitivity was improved in all 3 reviewers (94.0 to 99.2%; P < .05), and specificity was decreased (39.8 to 30.8%; P = .04). There was a significant increase of suspicion for malignancy with the patients’ CI (P < .05). Conclusions. Clinical information about a patient’s breast cancer history and clinical presentation with a palpable mass can increase the suspicion for malignancy on sonography and the sensitivity of sonographic interpretation.

Key Words: Breast Imaging Reporting and Data System lexicon • breast sonography • clinical information

Abbreviations: ACR, American College of Radiology • Az, area under the curve • BI-RADS, Breast Imaging Reporting and Data System • CI, clinical information • NPV, negative predictive value • PPV, positive predictive value • ROC, receiver operating characteristic







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2009 by the American Institute of Ultrasound in Medicine.