|
|
||||||||
|
by the American Institute of Ultrasound in Medicine J Ultrasound Med 27:1337-1344 0278-4297 Carotid Stenosis Assessed With a 4-Dimensional Semiautomated Doppler SystemDepartment of Radiology, Thomas Jefferson University, Philadelphia, Pennsylvania USA (F.F., D.A.M., K.J.L., L.P., L.N.); and VueSonix Sensors Inc, Wayne, Pennsylvania USA (A.D.S., D.H.). Dr Stein and Mr Herzog are currently with Seno Medical Instruments Inc, San Antonio, Texas USA. Address correspondence to Flemming Forsberg, PhD, Department of Radiology, Division of Ultrasound, Thomas Jefferson University, 132 S 10th St, Suite 763J, Main Building, Philadelphia, PA 19107 USA. E-mail: flemming.forsberg{at}jefferson.edu
Objective. The purpose of this study was to compare peak systolic velocities (PSVs) and the degree of stenosis obtained with a real-time 3-dimensional (ie, 4-dimensional) Doppler ultrasound scanner (Encore PV; VueSonix Sensors Inc, Wayne, PA) to conventional Doppler ultrasound imaging of the carotid arteries (common [CCA], internal [ICA], and external [ECA]). A secondary goal was to assess Encore volume flow measurements. Methods. Seventy patients referred for clinical carotid ultrasound participated in this pilot study. Peak systolic velocities of the CCA, ECA, and ICA were obtained bilaterally. The degree of stenosis in the ICA was calculated based on the ICA PSV and ICA/CCA PSV ratio. The Encore detects all 3-dimensional blood flow velocity vectors within 10-s longitudinal volumes of the ICA, ECA, and CCA. On the Encore, a reader determined the centerline of the vessels. The PSV and volume flow were then automatically calculated. The flow measurement error was obtained by comparing the CCA flow to the ICA and ECA flow. Data were compared using linear regression, intraclass correlation coefficients (ICCs), and Bland-Altman analysis. Results. Due to technical difficulties, only 59 patients (323 vessel segments) were available for analysis. There was good agreement between methods for assessing the degree of stenosis based on the ICA PSV (ICC = 0.83; P < .0001) and, to a lesser degree, on the ICA/CCA PSV ratio (ICC = 0.65; P < .0001). Peak systolic velocity measurements obtained with conventional ultrasound and the Encore correlated in all vessels (r
Key Words: carotid disease 4-dimensional color Doppler imaging real-time 3-dimensional Doppler imaging volume flow measurements Abbreviations: CCA, common carotid artery ECA, external carotid artery EDV, end-diastolic velocity 4D, 4-dimensional ICA, internal carotid artery ICC, intraclass correlation coefficient PRF, pulse repetition frequency PSV, peak systolic velocity RPSV, ICA/CCA PSV ratio 3D, 3-dimensional 2D, 2-dimensional
|
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |