by the American Institute of Ultrasound in Medicine J Ultrasound Med 27:1597-1606 0278-4297 Ultrasound-Mediated Release of Hydrophilic and Lipophilic Agents From Echogenic LiposomesDepartment of Biomedical Engineering, Colleges of Engineering and Medicine (J.A.K., T.M.A., B.W., S.M.C., D.A.B.S., C.K.H.), and Department of Radiology, College of Medicine (T.M.A.), University of Cincinnati, Cincinnati, Ohio, USA; Division of Cardiology, Department of Internal Medicine, University of Texas Health Science Center, Houston, Texas, USA (P.H.K., S.H., D.D.M); and Department of Surgery, College of Medicine, University of Chicago, Chicago, Illinois USA (J.H.C.). Address correspondence to Jonathan A. Kopechek, BS, Department of Biomedical Engineering, University of Cincinnati, 231 Albert Sabin Way, Medical Sciences Building, Room 6159, Cincinnati, OH 45267-0586 USA. E-mail: kopechja{at}uc.edu
Objective. To achieve ultrasound-controlled drug delivery using echogenic liposomes (ELIPs), we assessed ultrasound-triggered release of hydrophilic and lipophilic agents in vitro using color Doppler ultrasound delivered with a clinical 6-MHz compact linear array transducer. Methods. Calcein, a hydrophilic agent, and papaverine, a lipophilic agent, were each separately loaded into ELIPs. Calcein-loaded ELIP (C-ELIP) and papaverine-loaded ELIP (P-ELIP) solutions were circulated in a flow model and treated with 6-MHz color Doppler ultrasound or Triton X-100. Treatment with Triton X-100 was used to release the encapsulated calcein or papaverine content completely. The free calcein concentration in the solution was measured directly by spectrofluorimetry. The free papaverine in the solution was separated from liposome-bound papaverine by spin column filtration, and the resulting papaverine concentration was measured directly by absorbance spectrophotometry. Dynamic changes in echogenicity were assessed with low-output B-mode ultrasound (mechanical index, 0.04) as mean digital intensity. Results. Color Doppler ultrasound caused calcein release from C-ELIPs compared with flow alone (P < .05) but did not induce papaverine release from P-ELIPs compared with flow alone (P > .05). Triton X-100 completely released liposome-associated calcein and papaverine. Initial echogenicity was higher for C-ELIPs than P-ELIPs. Color Doppler ultrasound and Triton X-100 treatments reduced echogenicity for both C-ELIPs and P-ELIPs (P < .05). Conclusions. The differential efficiency of ultrasound-mediated pharmaceutical release from ELIPs for water- and lipid-soluble compounds suggests that water-soluble drugs are better candidates for the design and development of ELIP-based ultrasound-controlled drug delivery systems.
Key Words: calcein Doppler ultrasound drug release echogenic liposomes papaverine ultrasound Abbreviations: C-ELIP, calcein-loaded echogenic liposome ELIP, echogenic liposome MDI, mean digital intensity MI, mechanical index P-ELIP, papaverine-loaded echogenic liposome ROI, region of interest rt-PA, recombinant tissue plasminogen activator
|
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |