by the American Institute of Ultrasound in Medicine J Ultrasound Med 26:239-242 0278-4297
Three-Dimensional Sonography of Muscle HerniasChoithram Hospital and Research Centre, Indore, India. Address correspondence to Sudheer Gokhale, MBBS, MD, 53 Wasudevnagar, Indore 452004, India. E-mail: sudheergokhale{at}hotmail.com
Objective. Muscle hernias through a defect in the fascia can be subtle and difficult to see on 2-dimensional (2D) scans. We describe the appearance of muscle hernias on 3-dimensional (3D) sonographic multiplanar scans and 3D rendering. Methods. Two patients were examined with a 2D linear 5- to 12-MHz probe. The questionable area was scanned with a 5- to 12-MHz linear 3D transducer. Multiplanar reconstruction and 3D rendering were performed to show the hernia. Results. In both cases, the muscle hernia was small and subtle on 2D scans but became slightly more prominent on examination after the muscle was exercised. In both patients, the hernias were very obvious on 3D scans. Conclusions. Symptomatic muscle hernias may sometimes be very small and difficult to see on 2D scans. Three-dimensional rendering shows the hernia very well.
Key Words: hernia muscle 3-dimensional sonography Abbreviations: 3D, 3-dimensional 2D, 2-dimensional This article has been cited by other articles:
|
||||||||||||||