JUM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Nyhsen, C. M.
Right arrow Articles by Elliott, S. T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nyhsen, C. M.
Right arrow Articles by Elliott, S. T.
© 2007 by the American Institute of Ultrasound in Medicine
J Ultrasound Med 26:223-226 • 0278-4297


Technical Advance

Rapid Assessment of Abdominal Aortic Aneurysms by 3-Dimensional Ultrasonography

Christiane M. Nyhsen, MD, FRCR and Simon T. Elliott, MB, ChB, FRCR

Department of Radiology, Freeman Hospital, High Heaton, Newcastle Upon Tyne, England.

Address correspondence to Simon T. Elliott, MB, ChB, FRCR, Department of Radiology, Freeman Hospital, Freeman Road, High Heaton, Newcastle Upon Tyne NE7 7DN, England.

Objective. The purpose of this study was to assess the application and accuracy of 3-dimensional (3D) volume acquisition ultrasonography in the measurement of abdominal aortic aneurysms (AAAs). Methods. Thirty consecutive patients undergoing surveillance ultrasonographic examinations of known AAAs were scanned according to a conventional protocol, after which 3D volume data sets were acquired with a commercially available mechanical transducer. Maximum aortic diameters were measured with multiplanar reconstructions from the 3D volume data, and these were compared with those from the conventional technique. Results. Abdominal aortic aneurysm diameters were between 2.9 and 6.75 cm. For both anteroposterior and transverse diameters, a paired t test showed a Pearson correlation coefficient of 0.98 (significant at the P = .01 level) and a coefficient of determination of 0.96. Bland-Altman analysis showed that the mean difference between the two sets of measurements was very close to 0 (P = .05). Thus, there was no significant difference between the conventional and 3D volume measurement methods. The scan acquisition time for the 3D volume data was only 3 seconds for each set (anteroposterior and transverse). Conclusions. Three-dimensional ultrasonography using volume acquisition offers a new opportunity to acquire fast and reliable AAA measurements. The reduced scan times can be used to allow greater patient throughput and will help cope with the increasing workload of AAA surveillance. By archiving a complete set of data, 3D ultrasonography allows subsequent analysis and comparison of measurements. This study also suggests that the technique could be used for other applications with similar efficiency gains.

Key Words: abdominal aortic aneurysm • 3-dimensional ultrasonography • volume ultrasonography

Abbreviations: AAA, abdominal aortic aneurysm • AP, anteroposterior • 3D, 3-dimensional • 3DUS, 3-dimensional volume acquisition ultrasonography • TS, transverse




This article has been cited by other articles:


Home page
J Ultrasound MedHome page
B. S. John, D. Rowland, U. Patel, J. Pilcher, K. Anson, and D. Nassiri
Evaluation of the Accuracy of 3-Dimensional Ultrasonography of the Kidney Using an In Vitro Renal Model
J. Ultrasound Med., February 1, 2009; 28(2): 155 - 162.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
S T Elliott
Volume ultrasound: the next big thing?
Br. J. Radiol., January 1, 2008; 81(961): 8 - 9.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2007 by the American Institute of Ultrasound in Medicine.