JUM GE Healthcare
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Videos
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Huang, J.
Right arrow Articles by Dupont, P. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Huang, J.
Right arrow Articles by Dupont, P. E.
© 2007 by the American Institute of Ultrasound in Medicine
J Ultrasound Med 26:1303-1322 • 0278-4297

Imaging Artifacts of Medical Instruments in Ultrasound-Guided Interventions

Jinlan Huang, PhD, John K. Triedman, MD, Nikolay V. Vasilyev, MD, Yoshihiro Suematsu, MD, PhD, Robin O. Cleveland, PhD and Pierre E. Dupont, PhD

Department of Cardiology, Division of Basic Cardiovascular Research, Children’s Hospital Boston, Boston, Massachusetts USA (J.H., J.K.T., N.V.V.); Department of Cardiothoracic Surgery, University of Tokyo, Tokyo, Japan (Y.S.); and Department of Aerospace and Mechanical Engineering, Boston University, Boston, Massachusetts USA (R.O.C., P.E.D.).

Address correspondence to Pierre E. Dupont, PhD, Department of Aerospace and Mechanical Engineering, Boston University, 110 Cummington St, Boston, MA 02215 USA..,E-mail: pierre{at}bu.edu

Objective. Real-time 3-dimensional (3D) ultrasound imaging has the potential to become a dominant imaging technique for minimally invasive surgery. One barrier to its widespread use is that surgical instruments generate imaging artifacts, which can obfuscate their location, orientation, and geometry and obscure nearby tissue. The purpose of this study was to identify and describe the types of artifacts which could be produced by metallic instruments during interventions guided by 3D ultrasound imaging. Methods. Three imaging studies were performed. First, imaging artifacts from stainless steel rods were identified in vitro and acoustically characterized. Second, 3 typical minimally invasive instruments were imaged (in vitro and in vivo), and their artifacts were analyzed. The third study compared the intensity of imaging artifacts (in vitro and in vivo) from stainless steel rods with rods composed of 3 different materials and stainless steel rods with roughened and coated surfaces. Results. For the stainless steel rods, all observed artifacts are described and illustrated, and their physical origins are explained. Artifacts from the 3 minimally invasive instruments are characterized with the use of the artifacts observed with the rods. Finally, it is shown that artifacts can be greatly reduced through the use of alternate materials or by surface modification. Conclusions. Instrument artifacts in 3D ultrasound images can be more confusing than those from the same instruments imaged in 2 dimensions. Real-time 3D ultrasound imaging can, however, be used effectively for in vivo imaging of minimally invasive instruments by using artifact mitigation techniques, including careful selection of probe and incision locations, as well as by instrument modification.

Key Words: imaging artifacts • medical instruments • ultrasound-guided interventions

Abbreviations: 3D, 3-dimensional • 2D, 2-dimensional




This article has been cited by other articles:


Home page
J. Thorac. Cardiovasc. Surg.Home page
N. V. Vasilyev, I. Melnychenko, K. Kitahori, F. P. Freudenthal, A. Phillips, R. Kozlik-Feldmann, I. S. Salgo, P. J. del Nido, and E. A. Bacha
Beating-heart patch closure of muscular ventricular septal defects under real-time three-dimensional echocardiographic guidance: A preclinical study
J. Thorac. Cardiovasc. Surg., March 1, 2008; 135(3): 603 - 609.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2007 by the American Institute of Ultrasound in Medicine.