JUM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Video
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Braide, M.
Right arrow Articles by Bagge, U.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Braide, M.
Right arrow Articles by Bagge, U.
© 2006 by the American Institute of Ultrasound in Medicine
J Ultrasound Med 25:883-890 • 0278-4297

Microvascular Behavior and Effects of Sonazoid Microbubbles in the Cremaster Muscle of Rats After Local Administration

Magnus Braide, MD, PhD, Henrik Rasmussen, DVM, Ann Albrektsson and Ulf Bagge, MD, PhD

Department of Anatomy and Cell Biology, University of Göteborg, Göteborg, Sweden (M.B., A.A., U.B.); and GE Healthcare, Oslo, Norway (H.R.).

Address correspondence to Henrik Rasmussen, DVM, GE Healthcare AS, Research and Development, Nycoveien 2, PO Box 4220 Nydalen, N-0401 Oslo, Norway. E-mail: henrikrasmussen{at}ge.com

Objective. The purpose of this study was to observe Sonazoid perfluorobutane microbubbles (GE Healthcare, Amersham, Buckinghamshire, England) in and their effects on the cremaster capillary microcirculation of rats. Methods. Sonazoid (0.3 x 109 microbubbles in 0.5 mL) was observed by intravital microscopy in the cremaster muscle after retrograde administration into the femoral artery of 6 animals. Microbubble and microvessel diameters and blood flow velocities and the overall mean and SD of the 1-minute volume flow through the microscopic field were calculated from the 2 to 4 capillaries observed in the field of each animal. Fluorescein isothiocyanate-dextran leakage was used to assess extravasation after microbubble passage. Results.seconds, respectively, before they were released and capillary flow normalized. No microbubble size changes, damming, or coalescence of bubbles and no changes in microvessel diameter or microvascular blood flow velocities, volume flow, or perfusion heterogeneity occurred during or after the passage of the Sonazoid suspension or the vehicle. No fluorescein isothiocyanate-dextran leakage was observed. Conclusions. The passage of Sonazoid bubbles at concentrations higher than those expected after intravenous administration of the Sonazoid did not durably impair microvascular perfusion, structural integrity, or macromolecular retention in the rat cremaster muscle. The duration of discrete capillary obstructions was short and in all cases comparable with that of naturally occurring leukocyte plugging.

Key Words: capillary • fluorescein isothiocyanate • intra-arterial • Sonazoid • ultrasonographic contrast agent

Abbreviations: FITC, fluorescein isothiocyanate • IM, intravital microscopy • USCA, ultrasonographic contrast agent