JUM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Video
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Porter, T. M.
Right arrow Articles by Holland, C. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Porter, T. M.
Right arrow Articles by Holland, C. K.
© 2006 by the American Institute of Ultrasound in Medicine
J Ultrasound Med 25:1519-1529 • 0278-4297

Acoustic Techniques for Assessing the Optison Destruction Threshold

Tyrone M. Porter, PhD, Denise A. B. Smith, MS and Christy K. Holland, PhD

Department of Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio USA.

Address correspondence to Tyrone M. Porter, PhD, Department of Aerospace and Mechanical Engineering, Boston University, 110 Cummington St, Boston, MA 02215 USA. E-mail: tmp{at}bu.edu

Objective. The purpose of this study was to identify the pressure threshold for the destruction of Optison (octafluoropropane contrast agent; Amersham Health, Princeton, NJ) using a laboratory-assembled 3.5-MHz pulsed ultrasound system and a clinical diagnostic ultrasound scanner. Methods. A 3.5-MHz focused transducer and a linear array with a center frequency of 6.9 MHz were positioned confocally and at 90° to each other in a tank of deionized water. Suspensions of Optison (5–8 x 104 microbubbles/mL) were insonated with 2-cycle pulses from the 3.5-MHz transducer (peak rarefactional pressure, or Pr, from 0.0, or inactive, to 0.6 MPa) while being interrogated with fundamental B-mode imaging pulses (mechanical index, or MI, = 0.04). Scattering received by the 3.5-MHz transducer or the linear array was quantified as mean backscattered intensity or mean digital intensity, respectively, and fit with exponential decay functions (Aekt + N, where A + N was the amplitude at time 0; N, background echogenicity; and k, decay constant). By analyzing the decay constants statistically, a pressure threshold for Optison destruction due to acoustically driven diffusion was identified. Results. The decay constants determined from quantified 3.5-MHz radio frequency data and B-mode images were in good agreement. The peak rarefactional pressure threshold for Optison destruction due to acoustically driven diffusion at 3.5 MHz was 0.15 MPa (MI = 0.08). Furthermore, the rate of Optison destruction increased with increasing 3.5-MHz exposure pressure output. Conclusions. Optison destruction was quantified with a laboratory-assembled 3.5-MHz ultrasound system and a clinical diagnostic ultrasound scanner. The pressure threshold for acoustically driven diffusion was identified, and 3 distinct mechanisms of ultrasound contrast agent destruction were observed with acoustic techniques.

Key Words: acoustically driven diffusion • Optison • rapid fragmentation • static diffusion • ultrasound contrast agent destruction

Abbreviations: BSI, backscattered intensity • fc, center frequency • MGSV, mean gray scale value • MI, mechanical index • PBS, phosphate-buffered saline • Pr, peak rarefactional pressure • PRF, pulse repetition frequency • RF, radio frequency • ROI, region of interest • 2D, 2-dimensional • TGC, time-gain compensation • UCA, ultrasound contrast agent




This article has been cited by other articles:


Home page
J Ultrasound MedHome page
J. A. Kopechek, T. M. Abruzzo, B. Wang, S. M. Chrzanowski, D. A. B. Smith, P. H. Kee, S. Huang, J. H. Collier, D. D. McPherson, and C. K. Holland
Ultrasound-Mediated Release of Hydrophilic and Lipophilic Agents From Echogenic Liposomes
J. Ultrasound Med., November 1, 2008; 27(11): 1597 - 1606.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2006 by the American Institute of Ultrasound in Medicine.