JUM Parker Laboratories, Inc
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kripfgans, O. D.
Right arrow Articles by Fowlkes, J. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kripfgans, O. D.
Right arrow Articles by Fowlkes, J. B.
© 2006 by the American Institute of Ultrasound in Medicine
J Ultrasound Med 25:1305-1311 • 0278-4297


Technical Advance

Measurement of Volumetric Flow

Oliver D. Kripfgans, PhD, Jonathan M. Rubin, MD, PhD, Anne L. Hall, PhD, Michael B. Gordon, MD, PhD and J. Brian Fowlkes, PhD

Department of Radiology, University of Michigan, Ann Arbor, Michigan USA (O.D.K., J.M.R., M.B.G., J.B.F.); and GE Healthcare, Milwaukee, Wisconsin USA (A.L.H.).

Address correspondence to Oliver Kripfgans, PhD, Department of Radiology, University of Michigan, Kresge III, R3322, Ann Arbor, MI 48109-0553 USA. E-mail: oliver.kripfgans{at}umich.edu

Objective. The purpose of this study was to evaluate a 3-dimensional (3D) sonographic method for the measurement of volumetric flow under conditions of known flow rates and Doppler angles. Methods. A GE/Kretz Voluson 730 system (GE Healthcare, Milwaukee, WI) and RAB2-5 probe were used to acquire 3D Doppler measurements in a custom flow phantom. Blood-mimicking fluid circulated by a computer-controlled pump provided a range of flow velocities (2–15 mL/s). A 6-axis positioning system maneuvered the ultrasound probe through a range of angles (40°–70° and 110°–140°) with respect to the tube (orthogonal to the tube being 90°). Volume data sets were obtained spanning 29° lateral and 20° elevational angles encompassing the flow tube in a scanning time of less than 10 seconds. Power Doppler data were used to correct for partial volume effects. Results. Using a single angle (110°) with respect to the flow tube, measured and actual volume flow rates were within the 95% confidence interval over the full range of flow rates. At flow rates of 5 and 10 mL/s, the measured volume flow rates were all within ±15% of actual values for the range of angles tested and also stayed within the 95% confidence interval. Conclusions. Direct comparisons of volume flow rates estimated with 3D sonography and known flow rates showed that the method has good accuracy. Subsequent comparisons under pulsatile and in vivo conditions will be needed to verify this performance for clinical applications.

Key Words: color flow • Doppler sonography • flux • vector Doppler sonography • volume flow

Abbreviations: CF, color flow • ROI, region of interest • SIVV, surface integration of velocity vectors • 3D, 3-dimensional • VOI, volume of interest




This article has been cited by other articles:


Home page
J Ultrasound MedHome page
K. Hoyt, F. A. Hester, R. L. Bell, M. E. Lockhart, and M. L. Robbin
Accuracy of Volumetric Flow Rate Measurements: An In Vitro Study Using Modern Ultrasound Scanners
J. Ultrasound Med., November 1, 2009; 28(11): 1511 - 1518.
[Abstract] [Full Text] [PDF]


Home page
J Ultrasound MedHome page
F. Forsberg, A. D. Stein, D. A. Merton, K. J. Lipcan, D. Herzog, L. Parker, and L. Needleman
Carotid Stenosis Assessed With a 4-Dimensional Semiautomated Doppler System
J. Ultrasound Med., September 1, 2008; 27(9): 1337 - 1344.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2006 by the American Institute of Ultrasound in Medicine.