JUM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Clement, G. T.
Right arrow Articles by Hynynen, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Clement, G. T.
Right arrow Articles by Hynynen, K.
© 2005 by the American Institute of Ultrasound in Medicine
J Ultrasound Med 24:1117-1125 • 0278-4297


Technical Advance

A Magnetic Resonance Imaging–Compatible, Large-Scale Array for Trans-Skull Ultrasound Surgery and Therapy

Gregory T. Clement, PhD, FInstP, P. Jason White, MS, Randy L. King, MS, Nathan McDannold, PhD and Kullervo Hynynen, PhD

Department of Radiology, Harvard Medical School, Brigham and Women’s Hospital, Boston, Massachusetts 02115.

Address correspondence to Gregory T. Clement, PhD, FInstP, Department of Radiology, Harvard Medical School, Brigham and Women’s Hospital, 221 Longwood Ave, Room 521, Boston, MA 02115 USA. E-mail: gclement{at}hms.harvard.edu

Objective. Advances in ultrasound transducer array and amplifier technologies have prompted many intriguing scientific proposals for ultrasound therapy. These include both mildly invasive and noninvasive techniques to be used in ultrasound brain surgery through the skull. In previous work, it was shown how a 500-element hemisphere-shaped transducer could correct the wave distortion caused by the skull with a transducer that operates at a frequency near 0.8 MHz. Because the objective for trans-skull focusing is its ultimate use in a clinical context, a new hemispheric phased-array system has now been developed with acoustic parameters that are optimized to match the values determined in preliminary studies. Methods. The transducer was tested by focusing ultrasound through ex vivo human skulls and into a brain phantom by means of a phase-adaptive focusing technique. Simultaneously, the procedure was monitored by the use of magnetic resonance guidance and thermometry. Results. The ultrasound focus of a 500-element 30-cm-diameter, 0.81-MHz array could be steered electronically through the skull over a volume of approximately 30 x 30 x 26 mm. Furthermore, temperature monitoring of the inner and outer surfaces of the skull showed that the array could coagulate targeted brain tissue without causing excessive skull heating. Conclusions. The successful outcome of these experiments indicates that intensities high enough to destroy brain tissue can be produced without excessive heating of the surrounding areas and without producing large magnetic resonance noise and artifacts.

Key Words: phase aberration correction • thermal imaging • trans-skull therapy • ultrasound therapy

Abbreviations: CT, computed tomography • CW, continuous wave • MR, magnetic resonance • PZT, lead zirconate titanate




This article has been cited by other articles:


Home page
Ann. Surg. Oncol.Home page
D. Kopelman and M. Papa
Magnetic Resonance-Guided Focused Ultrasound Surgery for the Noninvasive Curative Ablation of Tumors and Palliative Treatments: A Review
Ann. Surg. Oncol., May 1, 2007; 14(5): 1540 - 1550.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2005 by the American Institute of Ultrasound in Medicine.