JUM etoc signup
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mari, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mari, G.
© 2005 by the American Institute of Ultrasound in Medicine
J Ultrasound Med 24:697-702 • 0278-4297


Review Article

Middle Cerebral Artery Peak Systolic Velocity

Is It the Standard of Care for the Diagnosis of Fetal Anemia?

Giancarlo Mari, MD

Department of Obstetrics and Gynecology, Wayne State University, Perinatology Research Branch, National Institute of Child Health and Human Development, National Institutes of Health, Department of Health and Human Services, Detroit, Michigan USA.

Address correspondence to Giancarlo Mari, MD, Department of Obstetrics and Gynecology, Wayne State University, Perinatology Research Branch, National Institute of Child Health and Human Development, National Institutes of Health, Department of Health and Human Services, Fourth Floor, Rush Center-PRB, 3990 John R, Detroit, MI 48201 USA.

Objective. The aim of this work was to review the use of middle cerebral artery peak systolic velocity (MCA PSV) for the diagnosis of fetal anemia. Methods. With the use of a computerized database (MEDLINE), articles on the diagnosis of fetal anemia with ultrasonography were reviewed. Other pertinent references were obtained from the references cited in these articles. In addition, my own institution’s clinical experience of the past 18 years was reviewed. Results. Several ultrasonographic parameters have been used to diagnose noninvasive fetal anemia. On the basis of robust data, the MCA PSV is the best ultrasonographic parameter used in the management of fetuses at risk for anemia due to different causes. It is also superior to amniocentesis for the diagnosis of fetal anemia in cases of red cell alloimmunization. Conclusions. Middle cerebral artery peak systolic velocity is effective for diagnosis of noninvasive moderate and severe fetal anemia. This parameter should not yet be considered the global standard of care for diagnosis of fetal anemia because incorrect use by an inexperienced operator may cause more harm than good; however, if there is a reasonably close medical center with sonographers or sonologists trained to assess the MCA PSV, patients at risk for fetal anemia should be referred to this center.

Key Words: fetal anemia • middle cerebral artery peak systolic velocity • pulsatility index • red cell alloimmunization

Abbreviations: MCA, middle cerebral artery • PSV, peak systolic velocity




This article has been cited by other articles:


Home page
NeoReviewsHome page
M. Marron-Corwin, F. Margono, and M. Meadows
Index of Suspicion in the Nursery
NeoReviews, January 1, 2009; 10(1): e39 - e41.
[Full Text] [PDF]


Home page
NEJMHome page
K. J. Moise Jr.
Diagnosing hemolytic disease of the fetus--time to put the needles away?
N. Engl. J. Med., July 13, 2006; 355(2): 192 - 194.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2005 by the American Institute of Ultrasound in Medicine.