JUM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lee, W.
Right arrow Articles by Romero, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lee, W.
Right arrow Articles by Romero, R.
© 2005 by the American Institute of Ultrasound in Medicine
J Ultrasound Med 24:201-207 • 0278-4297


Image Presentation

Inversion Mode

A New Volume Analysis Tool for 3-Dimensional Ultrasonography

Wesley Lee, MD, Luis F. Gonçalves, MD, Jimmy Espinoza, MD and Roberto Romero, MD

Division of Fetal Imaging, Department of Obstetrics and Gynecology, William Beaumont Hospital, Royal Oak, Michigan USA (W.L.); Perinatology Research Branch, National Institute of Child Health and Human Development, National Institutes of Health, Department of Health and Human Services, Bethesda, Maryland USA (W.L., L.F.G., J.E., R.R.); and Department of Obstetrics and Gynecology, Wayne State University, Detroit, Michigan USA (W.L., L.F.G., J.E., R.R.).

Address correspondence and reprint requests to Wesley Lee, MD, Division of Fetal Imaging, Department of Obstetrics and Gynecology, William Beaumont Hospital, 3601 W Thirteen Mile Rd, Royal Oak, MI 48073-6769 USA. E-mail: wlee{at}beaumont.edu

Objectives. The main goal was to introduce the inversion mode as a new image analysis tool for the examination of fluid-filled structures using 3-dimensional ultrasonography during pregnancy. Methods. Three-dimensional ultrasonography was performed on fetuses having fluid collections of noncardiac origin. Threshold adjustment was used to visually assign full transparency to voxels that were associated with fluid. A new postprocessing tool, called the inversion mode, was activated to transform this region of interest into opaque voxels. The morphologic appearance of fluid collections and their anatomic relationship to other organs were shown in this manner. Results. Diagnostic features were shown by this technique in several fetuses with problems that included pleural effusion, duodenal atresia, urinary tract abnormalities, and hydrocephaly. Furthermore, the inversion mode also permitted surface reconstruction of an irregular pleural effusion that had close resemblance to results with the Virtual Organ Computer-Aided Analysis rotational slice technique. Acoustic shadowing was also documented as a potential technical limitation of this method. Conclusions. The inversion mode can display scattered or contiguous fluid-filled structures in ways that can be very difficult or impossible to accurately characterize with conventional ultrasonography. It may be particularly helpful for the evaluation of multiple fluid-filled cysts or irregular fluid collections in the fetus.

Key Words: fetus • inversion mode • pregnancy • 3-dimensional ultrasonography

Abbreviations: ROI, region of interest • VOCAL, Virtual Organ Computer-Aided Analysis




This article has been cited by other articles:


Home page
Hum ReprodHome page
K. Jayaprakasan, N. Hilwah, N.R. Kendall, J.F. Hopkisson, B.K. Campbell, I.R. Johnson, and N.J. Raine-Fenning
Does 3D ultrasound offer any advantage in the pretreatment assessment of ovarian reserve and prediction of outcome after assisted reproduction treatment?
Hum. Reprod., July 1, 2007; 22(7): 1932 - 1941.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
B. R. Benacerraf
Inversion Mode Display of 3D Sonography: Applications in Obstetric and Gynecologic Imaging
Am. J. Roentgenol., October 1, 2006; 187(4): 965 - 971.
[Abstract] [Full Text] [PDF]


Home page
J Ultrasound MedHome page
B. R. Benacerraf, C. B. Benson, A. Z. Abuhamad, J. A. Copel, J. S. Abramowicz, G. R. DeVore, P. M. Doubilet, W. Lee, A. S. Lev-Toaff, E. Merz, et al.
Three- and 4-Dimensional Ultrasound in Obstetrics and Gynecology: Proceedings of the American Institute of Ultrasound in Medicine Consensus Conference
J. Ultrasound Med., December 1, 2005; 24(12): 1587 - 1597.
[Abstract] [Full Text] [PDF]


Home page
J Ultrasound MedHome page
L. F. Goncalves, W. Lee, J. Espinoza, and R. Romero
Three- and 4-Dimensional Ultrasound in Obstetric Practice: Does It Help?
J. Ultrasound Med., December 1, 2005; 24(12): 1599 - 1624.
[Abstract] [Full Text] [PDF]


Home page
J Ultrasound MedHome page
L. F. Goncalves, J. Espinoza, W. Lee, J. K. Nien, J.-S. Hong, J. Santolaya-Forgas, M. Mazor, and R. Romero
A New Approach to Fetal Echocardiography: Digital Casts of the Fetal Cardiac Chambers and Great Vessels for Detection of Congenital Heart Disease
J. Ultrasound Med., April 1, 2005; 24(4): 415 - 424.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2005 by the American Institute of Ultrasound in Medicine.