JUM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sheiner, E.
Right arrow Articles by Abramowicz, J. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sheiner, E.
Right arrow Articles by Abramowicz, J. S.
© 2005 by the American Institute of Ultrasound in Medicine
J Ultrasound Med 24:1665-1670 • 0278-4297

Acoustic Output as Measured by Mechanical and Thermal Indices During Routine Obstetric Ultrasound Examinations

Eyal Sheiner, MD, Jody Freeman, MD and Jacques S. Abramowicz, MD

Department of Obstetrics and Gynecology, Rush University Medical Center, Chicago, Illinois USA (E.S., J.S.A.); and Department of Obstetrics and Gynecology, University of Chicago Medical Center, Chicago, Illinois USA (J.F.).

Address correspondence to Jacques S. Abramowicz, MD, Department of Obstetrics and Gynecology, Rush University Medical Center, 1653 W Congress Pkwy, Chicago, IL 60612 USA. E-mail: jacques_abramowicz{at}rush.edu

Objective. The purpose of this study was to quantify the acoustic output of clinical ultrasound instruments, as expressed by the thermal index (TI) and mechanical index (MI), during routine obstetric examinations. Methods. A prospective, observational study was conducted. Sonographers were unaware of the data being sought. Data were collected regarding duration of the examination and specific duration spent at each MI and TI. Results. A total of 11 first-trimester, 14 second-trimester, and 12 third-trimester examinations were evaluated. The mean duration of the first-trimester examination was 8.9 minutes. The mean MI was 0.73 (range, 0.3–1.3), and the mean TI was 0.34 (0.1–1.7). The mean duration of the second-trimester examination was 31.8 minutes. The mean MI was 1.04 (0.5–1.5), and the mean TI was 0.28 (0.1–2.4). The mean duration of the third-trimester examination was 16.3 minutes. The mean MI was 1.06 (0.2–1.5), and the mean TI was 0.32 (0.1–2.4). Statistical significance existed across trimesters with regard to examination durations and MI (P < .001). However, no statistical significance existed in the TI across trimesters. During the third trimester, 3.5% of the examinations had a TI of greater than 1.0. Of these, 2.4% were between 1.0 and 1.49 and 1.1% were greater than 1.5. These changes (of TI ≥ 1) were brief (mean ± SD, 0.17 ± 0.08 minutes) and were observed during the short periods of color Doppler imaging. Conclusions. Output levels during routine obstetric ultrasound examinations, as expressed by the MI and TI, are generally low. However, higher output levels, particularly TI levels of greater than 1.5, can be achieved, although they account for only a very small proportion of examination time.

Key Words: acoustic output • mechanical index • pregnancy • safety • thermal index • ultrasound

Abbreviations: MI, mechanical index • ODS, Output Display Standard • TI, thermal index • TIB, TI for bones • TIS, TI for soft tissues




This article has been cited by other articles:


Home page
J Ultrasound MedHome page
E. Sheiner and J. S. Abramowicz
Clinical End Users Worldwide Show Poor Knowledge Regarding Safety Issues of Ultrasound During Pregnancy
J. Ultrasound Med., April 1, 2008; 27(4): 499 - 501.
[Full Text] [PDF]


Home page
J Ultrasound MedHome page
J. S. Abramowicz, S. B. Barnett, F. A. Duck, P. D. Edmonds, K. H. Hynynen, and M. C. Ziskin
Fetal Thermal Effects of Diagnostic Ultrasound
J. Ultrasound Med., April 1, 2008; 27(4): 541 - 559.
[Abstract] [Full Text] [PDF]


Home page
J Ultrasound MedHome page
E. Sheiner, I. Shoham-Vardi, and J. S. Abramowicz
What Do Clinical Users Know Regarding Safety of Ultrasound During Pregnancy?
J. Ultrasound Med., March 1, 2007; 26(3): 319 - 325.
[Abstract] [Full Text] [PDF]


Home page
J Ultrasound MedHome page
E. Sheiner, I. Shoham-Vardi, X. Pombar, M. J. Hussey, H. T. Strassner, and J. S. Abramowicz
An Increased Thermal Index Can Be Achieved When Performing Doppler Studies in Obstetric Sonography
J. Ultrasound Med., January 1, 2007; 26(1): 71 - 76.
[Abstract] [Full Text] [PDF]


Home page
Proc. Natl. Acad. Sci. USAHome page
V. S. Caviness and P. E. Grant
Our unborn children at risk?
PNAS, August 22, 2006; 103(34): 12661 - 12662.
[Full Text] [PDF]


Home page
J Ultrasound MedHome page
D. A. Toms
The Mechanical Index, Ultrasound Practices, and the ALARA Principle
J. Ultrasound Med., April 1, 2006; 25(4): 560 - 561.
[Full Text] [PDF]


Home page
J Ultrasound MedHome page
J. S. Abramowicz and E. Sheiner
Acoustic Output in Obstetric Ultrasound, ALARA and Education
J. Ultrasound Med., April 1, 2006; 25(4): 561 - 562.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2005 by the American Institute of Ultrasound in Medicine.