JUM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Unal, B.
Right arrow Articles by Kara, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Unal, B.
Right arrow Articles by Kara, S.
© 2004 by the American Institute of Ultrasound in Medicine
J Ultrasound Med 23:1041-1048 • 0278-4297

Evaluation of Differences Between Observers and Automatic-Manual Measurements in Calculation of Doppler Parameters

Birsen Unal, MD, Sebnem Bagcier, MD, Ilknur Simsir, MD, Yasemin Bilgili, MD and Simay Kara, MD

Department of Radiology, Kirikkale University School of Medicine, Suleyman Demirel Hospital, Kirikkale, Turkey.

Address correspondence and reprint requests to Birsen Unal, MD, Asiyan Sokak 11, 3 Subayevleri, Ankara 06130, Turkey. E-mail: birsenunal{at}hotmail.com.

Objective. We aimed to search for differences between observers and automatic and manual measurements in calculations of Doppler parameters. Methods. The middle cerebral artery (MCA), central retinal artery, ophthalmic artery (OA), common carotid artery (CCA), vertebral artery (VA), popliteal artery (PA), interlobar renal artery (IRA), and arcuate renal artery (ARA) were evaluated in 20 healthy subjects bilaterally. Peak systolic velocity (PSV), end-diastolic velocity (EDV), time-averaged maximum velocity (TAMAX), resistive index (RI), and pulsatility index (PI) were measured from the same spectrum manually by 3 observers and automatically. Results of 4 measurements were compared by analysis of variance and Pearson tests. Results. The comparison of the 4 measurements revealed significant differences for most parameters except TAMAX of the OA, VA, and ARA and PSV, EDV, and PI of the PA. An automatic calculator yielded lower PSV, RI, and PI values (except the MCA and PA) and higher EDV values compared with manual measurements. The magnitudes of difference were in the range of 1% to 16% for velocities and 4% to 14% for RI and PI. The means of difference were 3.185 cm/s for PSV of the CCA and 0.054 for RI of the IRA. Correlation was high for PSV, EDV, and TAMAX in all arteries (except TAMAX of PA) and relatively low for PI and RI in most of the arteries. Conclusions. Although our study was performed on healthy subjects, our results showed that, in most cases, readers and the automatic approach disagreed on evaluation of Doppler parameters. This may be important in preventing false diagnoses in cases with Doppler values close to upper limits and may necessitate establishment of new limits for each method.

Key Words: automatic calculation • automatic calculator • Doppler sonography • interobserver variability • manual measurement

Abbreviations: ARA, arcuate renal artery • CCA, common carotid artery • CRA, central retinal artery • EDV, end-diastolic velocity • IRA, interlobar renal artery • MCA, middle cerebral artery • MDV, minimum diastolic velocity • OA, ophthalmic artery • PA, popliteal artery • PI, pulsatility index • PSV, peak systolic velocity • RI, resistive index • TAMAX, time-averaged maximum velocity • VA, vertebral artery