JUM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rubaltelli, L.
Right arrow Articles by Rossi, C. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rubaltelli, L.
Right arrow Articles by Rossi, C. R.
© 2004 by the American Institute of Ultrasound in Medicine
J Ultrasound Med 23:829-836 • 0278-4297


Technical Advance

Evaluation of Lymph Node Perfusion Using Continuous Mode Harmonic Ultrasonography With a Second-Generation Contrast Agent

Leopoldo Rubaltelli, MD, Yeganeh Khadivi, MD, Alberto Tregnaghi, MD, Roberto Stramare, MD, Federica Ferro, MD, Simonetta Borsato, BD, Ugo Fiocco, MD, Fausto Adami, MD and Carlo Riccardo Rossi, MD

Departments of Medical Diagnostic Sciences and Special Therapies (L.R., Y.K., A.T., R.S., F.F.), Pathology (S.B.), Rheumatology (U.F.), Clinical and Experimental Medicine (F.A.), and Surgery (C.R.R.), University of Padua, Padua, Italy.

Address correspondence and reprint requests to Leopoldo Rubaltelli, MD, Department of Medical Diagnostic Sciences and Special Therapies, University of Padua, Via Giustiniani 2, 35128 Padua, Italy. E-mail: leopoldo.rubaltelli{at}unipd.it.

Objective. To evaluate the contribution of continuous mode contrast-enhanced harmonic ultrasonography (CE-HUS) with a second-generation contrast agent to the characterization of superficial lymphadenopathies with respect to conventional ultrasonographic techniques (B-mode and power Doppler). Methods. Fifty-six lymph nodes from 45 patients were studied both by conventional techniques and by CE-HUS. The dimensions, intranodal architecture, margins, and location of vessels were evaluated. Subsequently, all the lymph nodes were examined by CE-HUS, and enhancement of echogenicity was evaluated. The diagnoses obtained by means of fine-needle aspiration cytologic examination, surgical biopsy, or both were compared with those obtained by ultrasonography. Results. Of the lymph nodes examined, 30 were benign and 26 were malignant (18 metastases and 8 non-Hodgkin lymphomas). The study using CE-HUS showed intense homogeneous enhancement in 28 of 30 reactive lymph nodes; perfusion defects in 17, of which 15 were neoplastic and 2 were inflammatory; intense but inhomogeneous speckled enhancement in the early arterial phase in 5 cases of lymphoma; and, last, scarce or absent intranodal enhancement in 4 metastases. The specificity, sensitivity, and accuracy of conventional techniques in differentiation between benign and malignant lymph nodes were 76%, 80%, and 78% versus 93%, 92%, and 92.8% for CE-HUS. The increase in correct diagnoses was significant (P = .05) when conventional ultrasonography was tested against CE-HUS. Conclusions. Superficial lymph nodes can be characterized as being neoplastic or benign with a high degree of diagnostic accuracy on the basis of the perfusion characteristics evaluated by CE-HUS. This technique has been shown to afford a higher degree of accuracy than currently obtainable by any other ultrasonographic technique.

Key Words: contrast media • harmonic ultrasonography • lymphatic system • neoplasms

Abbreviations: CE-HUS, contrast-enhanced harmonic ultrasonography • CT, computed tomography • FNAC, fine-needle aspiration cytologic examination • HD, Hodgkin disease • MRI, magnetic resonance imaging




This article has been cited by other articles:


Home page
J Ultrasound MedHome page
Y. Huang, S. B. Hu, R. Wu, and F.-H. Xu
Detection of Small Inflammatory and Metastatic Lymph Nodes in Rabbits by Sonography: Evaluation With the Resistive Index Ratio
J. Ultrasound Med., February 1, 2008; 27(2): 233 - 241.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
L. Rubaltelli, S. Corradin, A. Dorigo, A. Tregnaghi, F. Adami, C. R. Rossi, and R. Stramare
Automated Quantitative Evaluation of Lymph Node Perfusion on Contrast-Enhanced Sonography
Am. J. Roentgenol., April 1, 2007; 188(4): 977 - 983.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2004 by the American Institute of Ultrasound in Medicine.