JUM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Testa, A. C.
Right arrow Articles by Ferrandina, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Testa, A. C.
Right arrow Articles by Ferrandina, G.
© 2004 by the American Institute of Ultrasound in Medicine
J Ultrasound Med 23:821-828 • 0278-4297


Technical Advance

Angiographic Power 3-Dimensional Quantitative Analysis in Gynecologic Solid Tumors

Feasibility and Reproducibility

Antonia Carla Testa, MD, Donata Mansueto, MD, Domenica Lorusso, MD, Erika Fruscella, MD, Danila Basso, MD, Giovanni Scambia, MD and Gabriella Ferrandina, MD

Department of Gynecology, Catholic University, Rome, Italy (A.C.T., D.M., E.F., D.B., G.F.); and Department of Oncology, Catholic University, Campobasso, Italy (D.L., G.S.).

Address correspondence and reprint requests to Antonia Carla Testa, MD, Department of Gynecology, Catholic University of the Sacred Heart, Largo A. Gemelli 8, 00168, Rome, Italy. E-mail: atesta{at}rm.unicatt.it.

Objective. To determine the reproducibility of a simplified method of power Doppler 3-dimensional (3D) sonographic examination. Methods. Twenty-nine patients with solid pelvic masses underwent transvaginal 3D power Doppler evaluation. The volume of interest was obtained by drawing the margins of the largest section of the mass in the 3 orthogonal planes. The 3D vascular parameters ("relative color," "average color," and "flow measure") obtained by our method were compared with those calculated by a manufacturer-suggested model based on several parallel section planes drawn on the longitudinal frames. The intraobserver variability was quantified on 5 different 3D images acquired by the same operator at 5-minute intervals for each patient. The intraobserver variability was also assayed in 10 patients at 24-hour intervals. Ten patients were scanned by a second sonographer for interobserver variability. Results. There was high agreement between the 3D parameters obtained with the 2 methods. The 3D indices were similar in repeated observations at 5-minute intervals (median coefficients of variation for relative color, average color, and flow measure, 10.9, 4.5, and 13.0, respectively) and at 24-hour intervals (intraclass correlation coefficients for relative color, average color, and flow measure, 0.920, 0.978, and 0.978) and by the second sonographer (interclass correlation coefficients for relative color, average color, and flow measure, 0.978, 0.966, and 0.997). Conclusions. The acceptable rates of intraobserver and interobserver variability make this approach potentially suitable for research protocols.

Key Words: angiogenesis • 3-dimensional power Doppler sonography • 3-dimensional sonography • transvaginal color Doppler sonography • transvaginal sonography

Abbreviations: CC, correlation coefficient • CI, confidence interval • CV, coefficient of variation • PSV, peak systolic velocity • TAMVX, time-averaged maximal velocity • 3D, 3-dimensional • 2D, 2-dimensional




This article has been cited by other articles:


Home page
J Ultrasound MedHome page
S. Guerriero, S. Ajossa, S. Piras, M. Gerada, S. Floris, N. Garau, L. Minerba, A. M. Paoletti, and G. B. Melis
Three-Dimensional Quantification of Tumor Vascularity as a Tertiary Test After B-Mode and Power Doppler Evaluation for Detection of Ovarian Cancer
J. Ultrasound Med., October 1, 2007; 26(10): 1271 - 1278.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2004 by the American Institute of Ultrasound in Medicine.