JUM Track the topics, authors and articles important to you
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lien, W. W.
Right arrow Articles by Mattrey, R. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lien, W. W.
Right arrow Articles by Mattrey, R. F.
© 2004 by the American Institute of Ultrasound in Medicine
J Ultrasound Med 23:683-691 • 0278-4297


Technical Advance

Noninvasive Estimation of the Pressure Gradient Across Stenoses Using Sonographic Contrast

In Vitro Validation

Winston W. Lien, MD, Allen H. Lee, MD, Yuko Kono, MD, Greg C. Steinbach, PhD and Robert F. Mattrey, MD

Department of Radiology, University of California, San Diego, San Diego, California USA.

Address correspondence and reprint requests to Robert F. Mattrey, MD, MRI Institute, University of California, San Diego, 410 Dickinson St, San Diego, CA 92103 USA. E-mail: rmattrey{at}ucsd.edu.

Objective. Because velocity measurements to estimate the degree of arterial stenosis are susceptible to local and systemic factors, we aimed to investigate the feasibility of estimating the pressure gradient across a stenosis noninvasively by using sonographic contrast. Methods. Using a gravity-fed flow system, a 1:4000 dilution of a contrast agent in water was circulated through silicone tubes that had either focal or long-segment stenoses of varying severity in a water bath. We measured the crosssectional areas of the normal and stenotic regions with B-mode sonography and the flow velocity with spectral Doppler sonography and calculated the pressure gradients across the stenoses using the empirically derived Young mathematical model and the simplified Bernoulli equation. Estimated gradients were compared with those measured manometerically. Results. Both methods yielded estimates of pressure gradients that correlated with measured gradients (r > 0.988). In focal and long-segment stenoses, the Young model yielded gradients that agreed more closely with manometerically measured values than the Bernoulli equation (±8% versus –24%–57%). Both methods were highly dependent on the ability to measure the luminal cross-sectional area. The presence of sonographic contrast in the vascular lumen highlighted the inner wall, allowing the accurate measurement of the luminal area to ±3.0%. Conclusions. The pressure gradient can be estimated across stenoses noninvasively. The Young model was more accurate than the simplified Bernoulli equation in this model using steady flow. Estimated gradients are highly dependent on the definition of the vascular lumen, a process aided by the use of sonographic contrast.

Key Words: arterial stenosis • Bernoulli equation • flow velocity • model • pressure gradient • Young method







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2004 by the American Institute of Ultrasound in Medicine.