JUM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lyon, M.
Right arrow Articles by Duggal, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lyon, M.
Right arrow Articles by Duggal, S.
© 2004 by the American Institute of Ultrasound in Medicine
J Ultrasound Med 23:677-681 • 0278-4297

Detection of Soft Tissue Foreign Bodies in the Presence of Soft Tissue Gas

Matt Lyon, MD, RDMS, Larry Brannam, MD, RDMS, Douglas Johnson, MD, Michael Blaivas, MD, RDMS and Sandeep Duggal, MD

Department of Emergency Medicine, Medical College of Georgia, Augusta, Georgia USA.

Address correspondence and reprint requests to Michael Blaivas, MD, RDMS, Department of Emergency Medicine, Medical College of Georgia, 1120 15th St, AF-2056, Augusta, GA 30912-4007. E-mail: mlyon{at}mail.mcg.edu.

Objective. To determine the effect of soft tissue gas on the accuracy of foreign body detection by real-time sonography. Methods. This was a prospective randomized study using glass, metal, and bone inserted into turkey breasts to simulate human soft tissue foreign bodies. Air was subsequently injected around a random selection of the foreign bodies to simulate soft tissue gas that can accompany a blast or high-force injury. Using a linear transducer, physicians credentialed in the use of sonography were each asked to scan the breasts, identify the location of any foreign body, and describe whether the object located was bone, metal, or glass. They were also asked to describe the characteristics of the foreign body, including surface echogenicity, visibility, and artifacts, if any. Results. The sensitivity for localization of each foreign body by each sonographer was 100% (48 of 48) and was unaffected by the presence of soft tissue gas. The accuracy of classifying the foreign body was poor except with bone. Glass and metal were often confused with each other. With the addition of soft tissue gas over the foreign bodies, the sensitivity of classifying the foreign body was decreased further from a combined 58% to 28%. The presence of soft tissue gas decreased the amount of reflection of the foreign body and obscured the subtle differences in the brightness of each foreign body, leading to a decrease in the accuracy of identification but not localization of the foreign body. Conclusions. In an experimental model, soft tissue gas does not affect the localization of soft tissue foreign bodies. However, correct identification of the type of foreign body is limited by soft tissue gas because of loss of the typical sonographic characteristics.

Key Words: crepitus • emergency sonography • foreign body • soft tissue gas • sonography




This article has been cited by other articles:


Home page
J Ultrasound MedHome page
D. Brylka, R. Abrams, R. Karlman, R. E. Besinger, and C. M. Dudiak
Sonographic Detection of an Unsuspected Intra-abdominal Surgical Sponge in a Pregnant Patient
J. Ultrasound Med., October 1, 2007; 26(10): 1445 - 1448.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2004 by the American Institute of Ultrasound in Medicine.