JUM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Nieckarz, Z.
Right arrow Articles by Rokita, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nieckarz, Z.
Right arrow Articles by Rokita, E.
© 2004 by the American Institute of Ultrasound in Medicine
J Ultrasound Med 23:527-533 • 0278-4297


Technical Advance

Geometry Corrections in a Rotating 3-Dimensional Sonographic System

Zenon Nieckarz, MSc, Grzegorz Taton, PhD and Eugeniusz Rokita, PhD

Department of Biophysics (Z.N., G.T., E.R.) and Institute of Physics (Z.N., E.R.), Jagiellonian University, Krakow, Poland.

Address correspondence and reprint requests to Grzegorz Taton, PhD, Department of Biophysics, Jagiellonian University, Grzegórzecka 16a, 31531 Krakow, Poland. E-mail: uftaton{at}cyf-kr.edu.pl.

Objective. To devise a system for geometry corrections in a rotating 3-dimensional sonographic system. Methods. A 3-dimensional sonographic imaging system based on a standard sonography machine was developed. The transducer mounted in a specially designed holder was rotated about its axis to acquire the spatial information. The most important postulate in rotating 3-dimensional systems is the assumption of parallelity between the rotation axis and the transducer axis. It allows the use of simple geometric relationships between 2-dimensional slices in a 3-dimensional reconstruction. The errors appearing in the 3-dimensional reconstruction when the axes are not parallel were investigated. Results. A simple correction method based on phantom measurements is proposed. The phantom contains a plane, which is inclined to the rotation axis. The analysis of 2-dimensional plane images allows the geometric corrections. The construction of the phantom is described, and the formulas used in the calculations are presented. The method was tested in computer simulations and in patient investigations. Conclusions. A complete method of the geometric investigations and corrections useful in 3-dimensional sonographic systems based on rotational geometry is proposed. Both the computer simulations and the phantom measurements confirmed the usefulness, precision, and simplicity of the proposed method.

Key Words: 3-dimensional imaging • 3-dimensional reconstruction • 3-dimensional sonography

Abbreviations: IA, image axis • IP, image plane • PP, phantom plane • RA, rotation axis • 3D, 3-dimensional • TA, transducer axis • 2D, 2-dimensional







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2004 by the American Institute of Ultrasound in Medicine.