JUM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ruano, R.
Right arrow Articles by Dommergues, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ruano, R.
Right arrow Articles by Dommergues, M.
© 2004 by the American Institute of Ultrasound in Medicine
J Ultrasound Med 23:403-408 • 0278-4297


Technical Advance

Volume Contrast Imaging

A New Approach to Identify Fetal Thoracic Structures

Rodrigo Ruano, MD, Alexandra Benachi, MD, Marie-Cecile Aubry, MD, Yves Dumez, MD and Marc Dommergues, MD

Maternité, Hôpital Necker-Enfants Malades, Paris, France.

Address correspondence and reprint requests to Rodrigo Ruano, MD, Maternité, Hôpital Necker-Enfants Malades, 149 rue de Sèvres, 75743 Paris Cedex 15, France. E-mail: rodrigoruano{at}hotmail.com.

Objective. To assess the potential of volume contrast imaging for evaluation of fetal intrathoracic structures. Methods. Volume contrast imaging is a new ultrasonographic method that increases the contrast between tissues. It consists of a 5- to 10-mm-thick slice-shaped volume image projected on a 2-dimensional screen. The rendering process applied on the slice smoothens the speckle pattern of the image by filling up the gaps with tissue information from the adjacent layers. To evaluate the potential of volume contrast imaging for enhancing the contrast between fetal lungs and surrounding tissues, we compared the ability of volume contrast imaging and conventional ultrasonography to image the fetal thymus in 50 controls. We also applied volume contrast imaging to prenatal imaging of 6 thoracic abnormalities (2 left congenital diaphragmatic hernias, 1 right diaphragmatic hernia, 2 congenital adenomatoid lung malformations, and 1 lung sequestration). Results. In controls, the thymus was identified in all cases by volume contrast imaging and in 42 cases (84%) by conventional 2-dimensional ultrasonography. Clear images of macrocystic and microcystic congenital adenomatoid malformations were obtained by volume contrast imaging, which provided precise contouring of the lesions. In cases with congenital diaphragmatic hernias, volume contrast imaging provided clear images of the limits of the lungs ipsilateral to the hernia. Conclusions. Volume contrast imaging may enhance the contrast between fetal lungs and surrounding organs and can be applied to prenatal imaging of intrathoracic structures in cases with thoracic fetal abnormalities.

Key Words: congenital adenomatoid lung malformation • congenital diaphragmatic hernia • congenital pulmonary sequestration • ultrasonography • 3-dimensional ultrasonography • volume contrast imaging

Abbreviations: 2D, 2-dimensional • 2DUS • 2-dimensional ultrasonography • VCI, volume contrast imaging




This article has been cited by other articles:


Home page
J Ultrasound MedHome page
R. Ruano, E. J. de A Pimenta, M. M. da Silva, J. G. Maksoud, and M. Zugaib
Percutaneous Intrauterine Laser Ablation of the Abnormal Vessel in Pulmonary Sequestration With Hydrops at 29 Weeks' Gestation
J. Ultrasound Med., September 1, 2007; 26(9): 1235 - 1241.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2004 by the American Institute of Ultrasound in Medicine.