JUM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lockhart, M. E.
Right arrow Articles by Allon, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lockhart, M. E.
Right arrow Articles by Allon, M.
© 2004 by the American Institute of Ultrasound in Medicine
J Ultrasound Med 23:161-168 • 0278-4297

Preoperative Sonographic Radial Artery Evaluation and Correlation With Subsequent Radiocephalic Fistula Outcome

Mark E. Lockhart, MD, MPH, Michelle L. Robbin, MD and Michael Allon, MD

Department of Radiology (M.E.L., M.L.R.) and Division of Nephrology (M.A.), University of Alabama at Birmingham, Birmingham, Alabama USA.

Address correspondence and reprint requests to Mark Lockhart, MD, MPH, Department of Radiology, University of Alabama at Birmingham, 619 19th St, South Birmingham, AL 35249-6830 USA. E-mail: mlockhar{at}uabmc.edu.

Objective. Primary failure of forearm radiocephalic dialysis fistulas is common even when preoperative vascular mapping is used. Previous studies have suggested that low peak systolic velocity of the radial artery predicts subsequent fistula failure. The study goal was to evaluate whether preoperative spectral Doppler assessment of radial artery inflow can improve forearm fistula outcome prediction. Methods. Forearm fistulas were placed in 112 patients after preoperative sonographic mapping. Preoperative spectral Doppler sonography measured radial artery peak systolic velocity during tight fist clenching for 3 minutes and after fist relaxation. Vessel diameters and peak systolic velocity were assessed for predictive value based on subsequent fistula adequacy. Fistula flow rates were determined 6 to 12 weeks postoperatively in a subset of patients. Results. Failed and successful fistulas were similar in their preoperative arterial and vein diameters, resistive index, and peak systolic velocity during fist clenching and after fist relaxation. Specifically, there was no difference in fistula success with radial artery peak systolic velocity lower than 50 cm/s versus peak systolic velocity of 50 cm/s or higher. The change in peak systolic velocity after fist relaxation was highly predictive of subsequent fistula outcome among female patients in ad hoc analysis. Fistula adequacy for dialysis in women was 11% when the change in peak systolic velocity was lower than 0 cm/s and 50% when the change was 0 cm/sec or higher (P = .02). The postoperative fistula flow rates were lower when the preoperative change in peak systolic velocity was lower than 0 cm/s than when it was 0 cm/s or higher (316 ± 46 versus 781 ± 150 mL/min; P = .003). Conclusions. There was no difference in the preoperative peak systolic velocity or the resistive index of successful and failed fistulas. Measurement of the radial artery peak systolic velocity change after release of fist clenching was not useful in predicting outcomes in male patients but identified a subset of female patients with a very low likelihood of success. This criterion may merit further investigation in future trials.

Key Words: arteries • Doppler sonography • fistula • hemodialysis, dialysis shunts • sex

Abbreviations: EDV, end-diastolic velocity • PSV, peak systolic velocity • RI, resistive index




This article has been cited by other articles:


Home page
Nephrol Dial TransplantHome page
F. Saucy, E. Haesler, C. Haller, S. Deglise, D. Teta, and J.-M. Corpataux
Is intra-operative blood flow predictive for early failure of radiocephalic arteriovenous fistula?
Nephrol. Dial. Transplant., November 5, 2009; (2009) gfp577v1.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
M. Ferring, J. Henderson, A. Wilmink, and S. Smith
Vascular ultrasound for the pre-operative evaluation prior to arteriovenous fistula formation for haemodialysis: review of the evidence
Nephrol. Dial. Transplant., June 1, 2008; 23(6): 1809 - 1815.
[Full Text] [PDF]


Home page
CJASNHome page
W. J. Peterson, J. Barker, and M. Allon
Disparities in Fistula Maturation Persist Despite Preoperative Vascular Mapping
Clin. J. Am. Soc. Nephrol., March 1, 2008; 3(2): 437 - 441.
[Abstract] [Full Text] [PDF]


Home page
CJASNHome page
C. E. Lok
Fistula First Initiative: Advantages and Pitfalls
Clin. J. Am. Soc. Nephrol., September 1, 2007; 2(5): 1043 - 1053.
[Full Text] [PDF]


Home page
J Ultrasound MedHome page
M. E. Lockhart, M. L. Robbin, N. S. Fineberg, C. G. Wells, and M. Allon
Cephalic Vein Measurement Before Forearm Fistula Creation: Does Use of a Tourniquet to Meet the Venous Diameter Threshold Increase the Number of Usable Fistulas?
J. Ultrasound Med., December 1, 2006; 25(12): 1541 - 1545.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2004 by the American Institute of Ultrasound in Medicine.