JUM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kamaya, A.
Right arrow Articles by Rubin, J. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kamaya, A.
Right arrow Articles by Rubin, J. M.
© 2004 by the American Institute of Ultrasound in Medicine
J Ultrasound Med 23:1597-1605 • 0278-4297

Characterization of a Linear Streak Artifact With Pulse Inversion Tissue Harmonics in Musculoskeletal Sonography

Aya Kamaya, MD, Sarah Abate, BS, Bin Nan, PhD, Inderpreet Grover, Ronald S. Adler, MD, PhD, David Jamadar, MBBS and Jonathan M. Rubin, MD, PhD

Departments of Radiology (A.K., S.A., I.G., D.J., J.M.R.) and Biostatistics (B.N.), University of Michigan, Ann Arbor, Michigan USA; and Department of Radiology, Hospital of Special Surgery, New York, New York USA (R.S.A.).

Address correspondence and reprint requests to Jonathan M. Rubin, MD, PhD, Department of Radiology, B1D502, 1500 E Medical Center Dr, Ann Arbor, MI 48109-0030 USA. E-mail: jrubin{at}umich.edu.

Objective. To understand a linear artifact that projects deep to reflective structures that move rapidly while using tissue harmonic imaging with pulse inversion (PI) sonography. We hypothesize that this artifact is due to a cancellation error between firings in PI imaging, and it is, therefore, similar in generation to the twinkling artifact in color Doppler sonography. This artifact could be studied with the use of surfaces of different roughness to represent different rates of motion, in which roughness corresponds to spatial fluctuations in surface height. Given very slight variations in beam focusing as occurs with sonographic imaging arrays, these spatial fluctuations translate into temporal fluctuations in the received signal as would occur with tissue motion. Methods. We scanned 4 different sandpaper grits and a smooth surface through a water path using fundamental and PI mode, 1- and 2-pulse techniques, respectively. The sandpaper and the smooth surface were scanned through a water path at mechanical indices of 0.1 to 0.7. Four independent images were subtracted pairwise to remove nonfluctuating signals. These noise pixels were counted and analyzed. Results. Analysis of variance showed that the noise generated behind the different surfaces was highly significantly different. Two-tailed t tests generally showed significant differences in the quantity of noise between fundamental and harmonic imaging behind the roughest 3 grades of sandpaper. A multiple regression model showed significantly greater slopes for harmonic imaging for all grades of sandpaper and the smooth surface. Conclusions. The noise and, by extension, the linear streak artifact in musculoskeletal imaging are dependent on the mechanical index and are functions of sandpaper roughness. This would be equivalent to a subtraction error between 2 firings due to soft tissue motion, and the artifact may be a way to identify rapid soft tissue motion in PI images.

Key Words: musculoskeletal sonography • pulse inversion • sonographic artifacts • tissue harmonic imaging

Abbreviations: MI, mechanical index • PI, pulse inversion • SOAB, sound-absorbing




This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
V. Khoury, E. Cardinal, and N. J. Bureau
Musculoskeletal Sonography: A Dynamic Tool for Usual and Unusual Disorders
Am. J. Roentgenol., January 1, 2007; 188(1): W63 - W73.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2004 by the American Institute of Ultrasound in Medicine.