JUM AIUM Career Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rose, S. C.
Right arrow Articles by Deutsch, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rose, S. C.
Right arrow Articles by Deutsch, R.
© 2004 by the American Institute of Ultrasound in Medicine
J Ultrasound Med 23:1465-1473 • 0278-4297

Display of 3-Dimensional Ultrasonographic Images for Interventional Procedures

Volume-Rendered Versus Multiplanar Display

Steven C. Rose, MD, Thomas R. Nelson, PhD and Reena Deutsch, PhD

Departments of Radiology (S.C.R., T.R.N.) and Family and Preventive Medicine (R.D.), University of California, San Diego Medical Center, San Diego, California USA.

Address correspondence and reprint requests to Steven C. Rose, MD, Department of Radiology, University of California, San Diego Medical Center, 200 W Arbor Dr, San Diego, CA 92103 USA. E-mail: scrose{at}ucsd.edu.

Objective. The goal of this project was to assess the display of 3-dimensional ultrasonographic images as used for interventional procedures, particularly the conspicuity of various targets and interventional devices, comparing volume-rendered (VR) versus multiplanar reformatted (MPR) display approaches. Methods. A series of ultrasonographic phantoms were made from a petroleum gel with cornstarch used to vary the echo texture. Three-dimensional ultrasonographic target and device conspicuity were judged with a 5-point visual rating scale. The MPR image was considered the reference standard. Volume-rendered image conspicuity was judged for combinations of 7 different postprocessing display parameters and compared with MPR images. Results. Definite visualization of the embedded objects occurred in 92% of MPR and 13% of VR test situations (P < .0001). Volume-rendered display was associated with a mean conspicuity degradation of 2.6 on a scale of 0 through 4 (P < .0001) compared with MPR methods. The proportion of satisfactory VR images was greatest in test situations with a large degree of difference of echogenicity between the background medium and the embedded object. The transparent-type postprocessing rendering modes were superior to the surface-type rendering modes (P < .0001). Conclusions. Current 3-dimensional ultrasonographic MPR imaging display in a solid organ environment provides better visualization performance of target and needle conspicuity than VR image display when there are not large differences in the signal levels of targeted structures and devices compared with surrounding tissues. The difficulty in viewing both target and device with VR imaging may restrict its ability to guide interventional procedures in some clinical situations.

Key Words: interventional procedures, experimental studies • interventional procedures, technology • ultrasonography • experimental studies • ultrasonography, guidance • ultrasonography, technology • ultrasonography, 3-dimensional

Abbreviations: MPR, multiplanar reformatted • RFA, radio frequency ablation • 3D, 3-dimensional • 3DUS, 3-dimensional ultrasonography • 2D, 2-dimensional • 2DUS, 2-dimensional ultrasonography • VR, volume-rendered







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2004 by the American Institute of Ultrasound in Medicine.