JUM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Goldstein, A.
Right arrow Articles by Arterbery, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Goldstein, A.
Right arrow Articles by Arterbery, E.
© 2002 by the American Institute of Ultrasound in Medicine
J Ultrasound Med 21:947-954 • 0278-4297

Design of Quality Assurance for Sonographic Prostate Brachytherapy Needle Guides

Albert Goldstein, PhD, Mark Yudelev, PhD, Renu K. Sharma, MS and Elayne Arterbery, MD

Department of Radiology (A.G.) and Gershenson Radiation Oncology Center, Karmanos Cancer Institute (M.Y., R.K.S., E.A.), Wayne State University School of Medicine, Detroit, Michigan.

Address correspondence and reprint requests to Albert Goldstein, PhD, Detroit Receiving Hospital, Radiology, 3L-8, 4201 St Antoine Blvd, Detroit, MI 48201.

Objective. Needles are guided to their proper anatomic locations in sonographically guided percutaneous prostate brachytherapy by a mechanical system (template). A quality assurance procedure has been designed to test this template’s alignment with the needle position overlay grid displayed in the sonographic image. Methods. A mechanical arrangement was designed to position the needles properly with respect to the prostate probe’s transducer in a liquid-filled test tank. Two liquids were tested: tap water and an ethylene glycol mixture with an acoustic velocity of 1540 m/s. Needle images with the superposed grid were analyzed for needle placement accuracy. Results. The tap water produced misregistration of the needle images. The ethylene glycol mixture yielded images of vertical and horizontal needle positions accurate to 0.3 and 1 mm, respectively. Also, the importance of selecting the lowest possible equipment echo amplitude dynamic range in these tests was shown. Conclusions. This quality assurance test with the ethylene glycol mixture will permit accurate alignment of the brachytherapy needle position overlay grid for each separate transrectal probe used.

Abbreviations: c, acoustic velocity • QA, quality assurance

Key Words: prostate brachytherapy • quality assurance • sonography