JUM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Heybeli, N.
Right arrow Articles by Mumcu, E. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Heybeli, N.
Right arrow Articles by Mumcu, E. F.
© 2002 by the American Institute of Ultrasound in Medicine
J Ultrasound Med 21:1357-1363 • 0278-4297

Diagnostic Ultrasound Treatment Increases the Bone Fracture–Healing Rate in an Internally Fixed Rat Femoral Osteotomy Model

Nurettin Heybeli, MD, Ahmet Yesildag, MD, Orhan Oyar, MD, Ufuk Kemal Gülsoy, MD, Mehmet Aslan Tekinsoy, PhD and Ethem Faruk Mumcu, MD

Departments of Orthopaedics and Traumatology (N.H., E.F.M.), Diagnostic Radiology (A.Y., O.O., U.K.G.), and Statistics (M.A.T.), Suleyman Demirel University, School of Medicine, Isparta, Turkey. Revision requested November 21, 2001. Revised manuscript accepted for publication April 11, 2002.

Address correspondence and reprint requests to Nurettin Heybeli, MD, Posta Kutusu 128, Isparta 32000, Turkey.

Objective. To investigate the healing effects of diagnostic ultrasound in a standardized rat femur fracture model. Methods. Thirty-two male rats aged 14 weeks were used, and each rat’s right femur was osteotomized and stabilized under anesthesia. The rats were then divided into 4 groups. Five days after surgery, ultrasound was applied every fifth day with diagnostic sonographic equipment and a probe with a 7.5-MHz frequency and 11.8-mW/cm2 total output intensity for 10 minutes in each session. Ultrasound was applied 8 times in group A, 3 times in group B, and only once in group C. Ultrasound was not applied to sham-operated group D. Healing and callus formation of the rats’ femur fractures were evaluated by radiography and dual-energy x-ray absorptiometry. Results. Dual-energy x-ray absorptiometric and radiographic results showed that the ultrasound therapy accelerated the fracture healing. Radiographically, groups A and B showed better fracture healing than groups C and D. Ultrasound exposure increased both the whole-bone mineral density and the density at the fracture region, increasing in parallel with the exposure period. Conclusions. This study confirms the previously shown efficacy of low-intensity ultrasonic stimulation in acceleration of the normal fracture repair process even when performed with a diagnostic sonographic device.

Key Words: bone density • bone fracture healing • rat • ultrasound

Abbreviations: DEXA, dual energy x-ray absorptiometry




This article has been cited by other articles:


Home page
J Ultrasound MedHome page
J. S. Abramowicz
Ultrasound in Obstetrics and Gynecology: Is This Hot Technology Too Hot?
J. Ultrasound Med., December 1, 2002; 21(12): 1327 - 1333.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2002 by the American Institute of Ultrasound in Medicine.