JUM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cozcolluela, M. R.
Right arrow Articles by Garcia, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cozcolluela, M. R.
Right arrow Articles by Garcia, S.

Journal of Ultrasound in Medicine, Vol 19, Issue 8 587-592, Copyright © 2000 by American Institute of Ultrasound in Medicine


JOURNAL ARTICLE

Correlation of central venous pressure with Doppler waveform of the common femoral veins

M. R. Cozcolluela, L. Sarria, L. Sanz, M. T. Martinez-Berganza, J. M. de Vera, A. Bernal and S. Garcia
Department of Radiology, Hospital Reina Sofia, Tudela, Navarra, Spain.

The objects of this prospective study were to determine the nature of the flow in the right femoral vein and to correlate the flow velocity with the venous pressure measured in the right atrium. We performed 236 pulsed Doppler ultrasonographic examinations in 1 year on patients with a venous catheter with the distal tip in the right atrium. In the Doppler wave readouts we analyzed wave frequency, velocity components, and relationships among them and the existence of pulsatile flow. These parameters were then compared to the right atrium pressure. We investigated the correlation between the atrium pressure and the flow velocity obtained from the Doppler waveforms of the common femoral veins, obtaining a significant correlation (P<0.0001) with the following: the atrium systolic wave a, the atrium diastolic wave v, the pulsatility ratio (PR = Vmin/Vmax) and the pulsatility index (PI = [Vmax - Vmin] /Vavg). The receiver operating characteristic showed that the pulsed Doppler ultrasonography is not a sensitive technique in diagnosis high atrium pressures. In addition, both cardiac and respiratory phasicity of the venous wave was observed. A significant inverse relation was found between the pulsatile flow and high atrium pressure. Nonetheless, the low sensitivity of this technique does not allow the use of pulsatile Doppler ultrasonography in the common femoral vein for diagnosing increases of the atrium pressure.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2000 by the American Institute of Ultrasound in Medicine.