JUM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Elgersma, O. E.
Right arrow Articles by van der Graaf, Y.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Elgersma, O. E.
Right arrow Articles by van der Graaf, Y.

Journal of Ultrasound in Medicine, Vol 18, Issue 3 191-201, Copyright © 1999 by American Institute of Ultrasound in Medicine


CLINICAL TRIAL

Lumen reduction measurements of the internal carotid artery before and after Levovist enhancement: reproducibility and agreement with angiography

O. E. Elgersma, M. S. van Leeuwen, R. Meijer, B. C. Eikelboom and Y. van der Graaf
Department of Radiology, Julius Center for Patient Oriented Research, University Hospital Utrecht, The Netherlands.

Our aim was to assess reproducibility of three different lumen reduction measuring methods--North American Symptomatic Carotid Endarterectomy Trial, European Carotid Surgery Trial, and common carotid--using power Doppler and color Doppler sonography before and after Levovist enhancement. We included 20 symptomatic patients with mild or severe carotid disease. North American Symptomatic Carotid Endarterectomy Trial, European Carotid Surgery Trial, and common carotid measurements on longitudinal views and European Carotid Surgery Trial measurements on transverse views were performed. Examinations were repeated and the results compared to assess reproducibility of measurements. Correlation with angiography was obtained by calculating Pearson correlation coefficients. Reproducibility was significantly better (P < 0.05) for European Carotid Surgery Trial and common carotid measurements (95% limits of agreement between -10% to 10% and -19% to 17%) as compared to North American Symptomatic Carotid Endarterectomy Trial measurements (95% limits of agreement between -11% to 21% and -21% to 23%). Variability of measurements after enhancement increased slightly (not significant) for both power and color Doppler sonography. Additionally, European Carotid Surgery Trial measurements, using nonenhanced power Doppler or color Doppler sonography, did not correlate significantly with angiography, whereas North American Symptomatic Carotid Endarterectomy Trial and common carotid measurements correlated well with angiography, particularly in power Doppler mode after enhancement (r = 0.88 and r = 0.82, respectively). We conclude that for lumen reduction measurements of the internal carotid artery with power and color Doppler sonography, the common carotid method is the only method that is reproducible and has good correlation with angiography, which slightly improves after Levovist enhancement.


This article has been cited by other articles:


Home page
RadiologyHome page
M. Claudon, D. Winninger, S. Briançon, and P. Pesque
Power Doppler US: Evaluation of the Morphology of Stenoses with a Flow Phantom
Radiology, January 1, 2001; 218(1): 109 - 117.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1999 by the American Institute of Ultrasound in Medicine.