JUM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Eicke, B. M.
Right arrow Articles by Paulus, W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Eicke, B. M.
Right arrow Articles by Paulus, W.

Journal of Ultrasound in Medicine, Vol 17, Issue 12 759-763, Copyright © 1998 by American Institute of Ultrasound in Medicine


JOURNAL ARTICLE

Volumetric measurements of the brachial and carotid arteries in dialysis grafts: is there evidence of a subclavian-carotid artery steal syndrome?

B. M. Eicke, C. Berwig, W. Wigger and W. Paulus
Department of Clinical Neurophysiology, Georg-August University Gottingen, Germany.

Dialysis grafts may lead to major hyperperfusion in the graft arm and to hypertrophic, hypervolemic cardiomyopathy. No data have been published concerning the impact of dialysis grafts on the cerebral perfusion in relation to a potential carotid steal syndrome, possibly causing neurologic or neuropsychologic symptoms. In 30 patients (32 to 74 years old) with dialysis grafts we studied the following hemodynamic parameters in the brachial and common carotid arteries bilaterally: Flow velocities (spectral Doppler sonography), diameter (B-mode) and volume flow (color M-mode) with a color duplex system (Philips P700). Volume flow in the brachial arteries of the graft arm averaged 1032 ml/min (range, 158 to 2854 ml/min) as compared to 42 ml/min (range, 15 to 108 ml/min) in the nongraft arm. Almost identical volume flow data could be seen in both common carotid arteries (418 versus 421 ml/min) with no evidence of reduced flow in the carotid arteries in patients with high flow in the graft arm. A tendency toward higher volume flow in both carotid arteries in patients with high volume flow in the graft arm was noted. We found no evidence of shunt-induced cerebral hypoperfusion. Cerebral autoregulation appears to be patent even with high brachial artery shunt volume.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1998 by the American Institute of Ultrasound in Medicine.