JUM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Order Full text via Infotrieve
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Jones, C. D.
Right arrow Articles by Clark, K. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jones, C. D.
Right arrow Articles by Clark, K. J.

Journal of Ultrasound in Medicine, Vol 16, Issue 4 269-274, Copyright © 1997 by American Institute of Ultrasound in Medicine


CLINICAL TRIAL

Color Doppler ultrasonographic detection of a vibrating needle system

C. D. Jones, J. P. McGahan and K. J. Clark
Department of Radiology, University of California, Davis, School of Medicine, USA.

The purpose of this study was to compare needle detection using a commercially available vibrating needle system that is used with color Doppler sonography and conventional real-time needle guidance during ultrasonographically guided intervention. Twenty-four paired (48 total) sonographically guided needle placements were performed in 22 patients for fine needle biopsy. Two patients underwent two additional needle placements at later times and, therefore, underwent a total of four needle passes each. Twenty-four of the needles were placed utilizing conventional real-time ultrasonographic guidance, and 24 were guided using a commercially available vibrating needle system. The Color Mark System was compared with standard technique for needle visualization and graded according to ease of needle visualization (improved, no change, or more difficult visualization). This was done for both needle tip and needle shaft visualization. Visualization was graded in both superficial (less than 3 cm deep) and deep structures. Overall needle tip and shaft visualization improved in 14 of 24 cases in superficial tissues and in three of 24 cases in superficial and deep tissues with the Color Mark System. The vibrating needle system also was judged to be somewhat cumbersome when used with a 22 gauge needle, as its weight tended to bend the needle shaft. The needle vibrating system may enhance needle visualization in superficial structures, but with the present design it is of limited use in deep tissues.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1997 by the American Institute of Ultrasound in Medicine.