JUM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Order Full text via Infotrieve
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Stikovac, M.
Right arrow Articles by Talley, J. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Stikovac, M.
Right arrow Articles by Talley, J. D.

Journal of Ultrasound in Medicine, Vol 14, Issue 3 211-215, Copyright © 1995 by American Institute of Ultrasound in Medicine


JOURNAL ARTICLE

Use of intravascular Doppler velocimetry during angioplasty of failing hemodialysis shunts

M. Stikovac and J. D. Talley
Section of Invasive and Interventional Cardiology, University of Louisville School of Medicine, Kentucky, USA.

To correlate angiographic stenoses, pressure gradients, and intravascular Doppler velocity measurements, we studied 12 patients with failing hemodialysis shunts who were undergoing percutaneous transluminal angioplasty. Seven patients had a stenosis at the site of venous anastomosis, two had a stenosis of the central vein, and three had stenoses at both sites. The mean degree of angiographic stenosis was reduced by percutaneous transluminal angioplasty from 74 +/- 8% to 23 +/- 7% diameter, and the mean pressure gradient was reduced from 48 +/- 13 to 7 +/- 3 mm Hg. The proximal to distal peak systolic velocity ratio was significantly different before and after the angioplasty (3.3 +/- 1.4 and 1.6 +/- 0.6, respectively, P < 0.001). The lesion to proximal peak systolic velocity ratio was 2.5 +/- 0.8 before and 1.2 +/- 0.2 after percutaneous transluminal angioplasty (P < 0.001). Cutoff values of 1.9 for the proximal to distal velocity ratio and 1.5 for lesion to proximal velocity ratio were used to assess hemodynamic significance of lesions in our series. Velocity gradients derived from intravascular Doppler measurements correlate with angiographic and pressure measurements in failing hemodialysis shunts treated with percutaneous transluminal angioplasty. Further studies are needed to assess the exact role of these measurements in percutaneous revascularization procedures.


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
G. X. Zaleski, B. Funaki, J. Rosenblum, J. Theoharis, and J. Leef
Metallic Stents Deployed in Synthetic Arteriovenous Hemodialysis Grafts
Am. J. Roentgenol., June 1, 2001; 176(6): 1515 - 1519.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1995 by the American Institute of Ultrasound in Medicine.