JUM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Order Full text via Infotrieve
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sehgal, C. M.
Right arrow Articles by Pugh, C. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sehgal, C. M.
Right arrow Articles by Pugh, C. R.

Journal of Ultrasound in Medicine, Vol 14, Issue 10 741-748, Copyright © 1995 by American Institute of Ultrasound in Medicine


JOURNAL ARTICLE

Sonographic enhancement of renal cortex by contrast media

C. M. Sehgal, P. H. Arger and C. R. Pugh
Hospital of the University of Pennsylvania, Philadelphia, USA.

The purpose of this study was to evaluate whether a phase shift contrast agent could enhance the renal cortex. Four doses of the contrast agent EchoGen ranging from 0.25 to 0.65 ml/kg were injected intravenously in three healthy dogs. Images of the kidney were recorded on a videotape before and after each injection. The images were evaluated visually and were computer-analyzed for brightness change caused by the contrast agent. Marked changes in cortical brightness were observed at the doses of 0.45 and 0.65 ml/kg. At lower doses the changes in image brightness were significantly reduced but measurable. The brightness peaked at 65 +/- 9 seconds after injection and gradually decreased to the baseline value in approximately 12 minutes. The video density varied nonlinearly with dose, and at low doses its value drifted below the baseline. This is believed to be due to attenuation of echoes by the contrast agent. The results of this study indicate that the microbubbles formed by phase shift contrast media are sufficiently small and persist long enough to enhance sonographic images of the cortex. Contrast media whose effect is based on the phenomenon of phase shift permit enhancement of the gray scale characteristic of the kidney. The enhancements last up to several minutes and have strong potential to allow investigation of perfusion in kidney.


This article has been cited by other articles:


Home page
J Ultrasound MedHome page
J. H. Kim, H. W. Eun, H. J. Lee, D. E. Goo, and D. L. Choi
Clinical Use of Renal Perfusion Imaging by Means of Harmonic Sonography With a Microbubble Contrast Agent in Patients After Renal Transplantation: Preliminary Study
J. Ultrasound Med., June 1, 2005; 24(6): 755 - 762.
[Abstract] [Full Text] [PDF]


Home page
Journal of Diagnostic Medical SonographyHome page
C. L. Peterson and R. G. Barr
Contrast-Enhanced Sonography in Patients with Renal Pathology
Journal of Diagnostic Medical Sonography, March 1, 2000; 16(2): 53 - 56.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1995 by the American Institute of Ultrasound in Medicine.