JUM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Order Full text via Infotrieve
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Nicolau, C.
Right arrow Articles by Vilana, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nicolau, C.
Right arrow Articles by Vilana, R.

Journal of Ultrasound in Medicine, Vol 12, Issue 8 437-440, Copyright © 1993 by American Institute of Ultrasound in Medicine


JOURNAL ARTICLE

Sonographic diagnosis and hemodynamic correlation in veno-occlusive disease of the liver

C. Nicolau, C. Bru, E. Carreras, J. Bosch, L. Bianchi, R. Gilabert and R. Vilana
Department of Radiology, Hospital Clinic i Provincial, Barcelona, Spain.

This study evaluated the role of duplex Doppler sonography in the diagnosis of VOD of the liver after bone marrow transplantation. Sixteen patients with clinical criteria of VOD were studied. The final diagnosis was achieved by transjugular liver biopsy, and the hepatic venous pressure gradient was measured during the procedure to estimate portal pressure. Nine patients (56.2%) had histologically proved VOD. Gallbladder wall thickening was present in 75% of patients with VOD, but in none of those without it (P = 0.01). Gallbladder wall thickening and ascites were present only in patients with portal hypertension. Nine patients (five with VOD and four without it) also were evaluated with duplex Doppler sonography, and no obvious flow abnormalities were detected in the portal vein and hepatic veins. These results suggest that sonography is useful in detecting early signs of portal hypertension pointing to the diagnosis of VOD in patients with bone marrow transplantation.


This article has been cited by other articles:


Home page
ImagingHome page
S A Sohaib
Extrapulmonary complications of bone marrow transplantation
Imaging, August 1, 2002; 14(4): 278 - 284.