JUM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Order Full text via Infotrieve
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Strauss, A. L.
Right arrow Articles by Rieger, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Strauss, A. L.
Right arrow Articles by Rieger, H.

Journal of Ultrasound in Medicine, Vol 12, Issue 1 17-22, Copyright © 1993 by American Institute of Ultrasound in Medicine


JOURNAL ARTICLE

Noninvasive assessment of pressure gradients across iliac artery stenoses: duplex and catheter correlative study

A. L. Strauss, F. J. Roth and H. Rieger
Department of Medicine, Hospital for Vascular Diseases, Engelskirchen, Germany.

The present study investigates prospectively the validity and accuracy of the simplified Bernoulli equation in the duplex-derived determination of pressure gradients across iliac artery stenoses in patients with occlusive artery disease. In 28 patients (age range, 38 to 76 years; mean, 53 years) with short iliac artery stenoses, we obtained both duplex scan stenotic jet velocity and catheter pressure measurements. Mean and maximum pressure gradients were determined by both methods, as was the peak-to-peak catheter gradient. The correlation between the duplex-determined and nonsimultaneously measured catheter mean pressure gradients was r = 0.77 (standard error of the estimate [SEE] = 5 mm Hg), that between the duplex-derived and catheter-determined maximum pressure gradients was r = 0.80 (SEE = 10 mm Hg), and that between maximum duplex-determined and peak-to-peak catheter gradient was r = 0.76 (SEE = 12 mm Hg). The peak-to-peak catheter gradient was significantly lower than the maximum duplex-derived gradient (46 versus 53 mm Hg, P < 0.05). Duplex-determined mean pressure gradient decreased from 15 +/- 6 to 3 +/- 1 mm Hg after balloon angioplasty of the iliac stenoses. Duplex scan can be used to predict pressure gradients across short iliac artery stenoses, provided that errors caused by angle malcompensation are prevented.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1993 by the American Institute of Ultrasound in Medicine.