JUM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Order Full text via Infotrieve
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Miller, D. L.
Right arrow Articles by Williams, A. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Miller, D. L.
Right arrow Articles by Williams, A. R.

Journal of Ultrasound in Medicine, Vol 11, Issue 8 407-412, Copyright © 1992 by American Institute of Ultrasound in Medicine


JOURNAL ARTICLE

Nucleation and evolution of ultrasonic cavitation in a rotating exposure chamber

D. L. Miller and A. R. Williams
Battelle Pacific Northwest Laboratories, Richland, Washington 99352.

The nucleation and progression of ultrasonic cavitation in a rotating exposure chamber were investigated by observing hemolysis of a 0.5% suspension of erythrocytes. Bursts of 1.6 MHz ultrasound beams of 11 W/cm2 spatial peak intensity were synchronized with the rotation to aim the bursts down the axis of a cylindrical chamber. Cavitational hemolysis always occurred in fresh phosphate buffered saline (PBS) solution, but cavitation incidence declined to 38% in 4 day old PBS. The amount of hemolysis for 11 ms or 44 ms bursts with 60 rpm rotation increased in proportion to the number of bursts. Hemolysis was found above a minimum burst duration of 5.5 to 8.3 ms in the normal 2 cm chamber. This did not appear to change for 1 cm or 4 cm chamber lengths, but it did change to about 2.2 ms and about 44 ms for over- and undersaturated gas conditions, respectively. Off-times associated with rotation speeds of 15 to 30 rpm reduced the effectiveness of the cavitation, and addition of fixed cells at only 0.01% to 0.02% greatly reduced the hemolysis. For this ultrasonic exposure system, several thousand bubbles, possibly generated from as few as one cavitation nucleus, move across the chamber at up to 10 m/s, each lysing a few hundred cells, and then are cycled back to the front of the chamber by the rotation to reinitiate the cavitation on the next burst.


This article has been cited by other articles:


Home page
Appl. Environ. Microbiol.Home page
A. C. Vollmer, S. Kwakye, M. Halpern, and E. C. Everbach
Bacterial Stress Responses to 1-Megahertz Pulsed Ultrasound in the Presence of Microbubbles
Appl. Envir. Microbiol., October 1, 1998; 64(10): 3927 - 3931.
[Abstract] [Full Text]