We have constructed a three-dimensional (3-D) ultrasound scanner to make
examinations easier and more accurate. The accuracy of the 3-D scanner has
been determined by scanning a three-dimensional model. Lengths, angles, and
volume of the model were computed and compared to values determined from
physical measurement. Distances between image planes were computed with a
mean error of 0.4% of true value. Volume was computed with a mean error of
1.6%, or 0.64 mL +/- 0.72 mL (1 SD). We conclude that the 3-D scanner has a
system error of less than 0.4%, that it does not introduce significant new
errors, and that the principal source of measurement error is poor lateral
resolution due to ultrasound beam width. We believe that the 3-D scanner
may be a clinically useful instrument for quantitative echographic
measurements.
This article has been cited by other articles:

|
 |

|
 |
 
H. Osada, Y. Iitsuka, K. Masuda, R. Sakamoto, K. Kaku, K. Seki, and S. Sekiya
Application of Lung Volume Measurement by Three-dimensional Ultrasonography for Clinical Assessment of Fetal Lung Development
J. Ultrasound Med.,
August 1, 2002;
21(8):
841 - 847.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
D. L. King, L. El-Khoury Coffin, and M. S. Maurer
Myocardial contraction fraction: a volumetric index of myocardial shortening by freehand three-dimensional echocardiography
J. Am. Coll. Cardiol.,
July 17, 2002;
40(2):
325 - 329.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
K. R. Duncan, D. S. Sahota, P. A. Gowland, R. Moore, A. Chang, P. N. Baker, and I. R. Johnson
Multilevel Modeling of Fetal and Placental Growth Using Echo-Planar Magnetic Resonance Imaging
Reproductive Sciences,
September 1, 2001;
8(5):
285 - 290.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
T.-B. SONG, T. R. MOORE, J.-Y. LEE, Y.-H. KIM, and E.-K. KIM
Fetal Weight Prediction by Thigh Volume Measurement With Three-Dimensional Ultrasonography
Obstet. Gynecol.,
August 1, 2000;
96(2):
157 - 161.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
J. Bakker, M. Olree, R. Kaatee, E. E. de Lange, K. G. M. Moons, J. J. Beutler, and F. J. A. Beek
Renal Volume Measurements: Accuracy and Repeatability of US Compared with That of MR Imaging
Radiology,
June 1, 1999;
211(3):
623 - 628.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
K. R. Duncan, P. A. Gowland, R. J. Moore, P. N. Baker, and I. R. Johnson
Assessment of Fetal Lung Growth in Utero with Echo-planar MR Imaging
Radiology,
January 1, 1999;
210(1):
197 - 200.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
Y. F.M. Nosir, P. M. Fioretti, W. B. Vletter, E. Boersma, A. Salustri, J. T. Postma, A. E.M. Reijs, F. J. Ten Cate, and J. R.T.C. Roelandt
Accurate Measurement of Left Ventricular Ejection Fraction by Three-dimensional Echocardiography: A Comparison With Radionuclide Angiography
Circulation,
August 1, 1996;
94(3):
460 - 466.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
A. S. Gopal, Z. Shen, P. M. Sapin, A. M. Keller, M. J. Schnellbaecher, D. W. Leibowitz, O. O. Akinboboye, R. A. Rodney, D. K. Blood, and D. L. King
Assessment of Cardiac Function by Three-dimensional Echocardiography Compared With Conventional Noninvasive Methods
Circulation,
August 15, 1995;
92(4):
842 - 853.
[Abstract]
[Full Text]
|
 |
|
|
|