|
|
||||||||
|
Journal of Ultrasound in Medicine, Vol 10, Issue 12 671-675, Copyright © 1991 by American Institute of Ultrasound in Medicine
Influence of the measurement location on the resistance index in the umbilical arteries: a hemodynamic approach
P. Vieyres, A. Durand, F. Patat, P. Descamps, J. M. Gregoire, D. Pourcelot and L. Pourcelot
A computer model was used to study the primary factors generating the reduction in resistance index, (S-D)/S, values observed by ultrasonic Doppler measurements in the umbilical artery, from the fetal insertion to the placental insertion (S represents the amplitude of the systolic peak and D the amplitude of the diastolic peak). This hemodynamic approach shows that the placental resistance is the primary factor, the viscosity and the cord length playing secondary roles. Clinically, the position of the measurement along the cord is an important factor. To increase the sensitivity of the index, the Doppler measurement must be performed near the fetal insertion, whereas a measurement near the placental insertion will make the Doppler examination more specific. |
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |