JUM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Order Full text via Infotrieve
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Davies, R. P.
Right arrow Articles by Toouli, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Davies, R. P.
Right arrow Articles by Toouli, J.

Journal of Ultrasound in Medicine, Vol 10, Issue 12 653-657, Copyright © 1991 by American Institute of Ultrasound in Medicine


JOURNAL ARTICLE

Contrast cholangiography versus ultrasonographic measurement of the "extrahepatic" bile duct: a two-fold discrepancy revisited

R. P. Davies, P. R. Downey, W. R. Moore, P. L. Jeans and J. Toouli
Department of Radiology, Flinders Medical Centre, Bedford Park, South Australia.

The upper limit of the normal extrahepatic duct diameter when measured by sonography in our institution is less than half that when measured by endoscopic retrograde cholangiopancreatography (ERCP). The objective of this study was to locate possible sources of this discrepancy by comparing measurements obtained on the same patient by sonography, before and after ERCP. Thirty consecutive patients referred for ERCP were entered into a prospective trial; bile duct measurements were obtained independently by both techniques in 19 patients. Correcting for radiographic magnification, the ERCP measurement was more than twice that obtained by ultrasonography. Among the possible reasons for diverse results that we considered, radiographic magnification, ultrasonic underestimation, and distending effects of retrograde cholangiography (ERCP) were not found to be prominent causes for the marked discrepancy that we observed. The most likely explanation is that the duct in individual patients was being measured at a different level by the two techniques. A retrospective comparison of the studies obtained by each method suggests that the sonographic measurement is most often of the right hepatic duct. If this is the case, the two measurements show no statistically significant difference (P greater than 0.05). A prospective trial is needed to test this hypothesis.